United Kingdom
Welcome to the Schneider Electric Website

Welcome to our website.

You can choose another country to view available products or go to our Global website for company information.

Select your location
View all Preventa XPS
Schneider Eletric XPSABV1133C Picture

XPSABV1133C

Green premium brand logo
Schneider Eletric XPSABV1133C Picture
XPSABV1133C
Green premium brand logo

module XPSABV - stop and switch monitoring - 24 V AC/DC

Show more characteristics
  • RRP
    167.00 GBP
Add to My Products Remove from My Products
The maximum number of products that can be compared is 4

  • Main
    range of product
    Preventa Safety automation
    product or component type
    Preventa safety module
    safety module name
    XPSABV
    safety module application
    For emergency stop and switch monitoring
    safety level
    Can reach PL d/category 3 time delay safety outputs conforming to EN/ISO 13849-1
    Can reach PL e/category 4 instantaneous safety outputs conforming to EN/ISO 13849-1
    Can reach SILCL 3 instantaneous safety outputs conforming to EN/IEC 62061
    Can reach SILCL 2 time delay safety outputs conforming to EN/IEC 62061
    safety reliability data
    MTTFd = 53 years conforming to EN/ISO 13849-1 instantaneous safety outputs
    MTTFd = 53 years conforming to EN/ISO 13849-1 time delay safety outputs
    DC > 99 % conforming to EN/ISO 13849-1 instantaneous safety outputs
    DC = 60...90 % conforming to EN/ISO 13849-1 time delay safety outputs
    PFHd = 3E-8 1/h conforming to EN/IEC 62061 instantaneous safety outputs
    PFHd = 2E-7 1/h conforming to EN/IEC 62061 time delay safety outputs
    connections - terminals
    Spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid without cable end
    Spring terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible without cable end
    Spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel
    Spring terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel
    Spring terminals, removable terminal block, 2 x 0.5...2 x 1 mm² flexible with cable end, with double bezel
    Spring terminals, removable terminal block
    output type
    Relay instantaneous opening, 2 NO circuit(s), volt-free
    Relay time delay opening, 1 NO circuit(s), volt-free
    number of additional circuits
    0
    [Us] rated supply voltage
    24 V DC - 15...10 %
    Complementary
    synchronisation time between inputs
    < 0.5 s
    maximum power consumption in W
    3 W
    input protection type
    Internal, electronic
    time delay range
    0.15...3 s
    1.5...30 s
    [Uc] control circuit voltage
    24 V DC
    breaking capacity
    3600 VA inrush AC-15 B300
    360 VA holding AC-15 B300
    breaking capacity
    1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
    output thermal current
    6 A for instantaneous and time delay outputs
    [Ith] conventional free air thermal current
    12 A
    associated fuse rating
    6 A gG for instantaneous and time delay outputs
    minimum output current
    10 mA for relay output
    minimum output voltage
    17 V for relay output
    maximum response time on input open
    200 ms
    [Ui] rated insulation voltage
    300 V (pollution degree 2) conforming to IEC 60947-5-1
    300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
    [Uimp] rated impulse withstand voltage
    4 kV overvoltage category III conforming to IEC 60947-5-1
    4 kV overvoltage category III conforming to DIN VDE 0110 part 1
    local signalling
    3 LEDs
    mounting support
    35 mm symmetrical DIN rail
    net weight
    0.275 kg
    Environment
    standards
    EN/IEC 60947-5-1
    EN 1088/ISO 14119
    EN/IEC 60204-1
    EN/ISO 13850
    product certifications
    UL
    BG
    CSA
    IP degree of protection
    IP20 conforming to EN/IEC 60529
    IP40 conforming to EN/IEC 60529
    ambient air temperature for operation
    -25…55 °C
    ambient air temperature for storage
    -25…75 °C
    Offer Sustainability
    Sustainable offer status
    Green Premium product
    REACh Regulation
    REACh free of SVHC
    Yes
    EU RoHS Directive
    Pro-active compliance (Product out of EU RoHS legal scope)
    EU RoHS Declaration
    Toxic heavy metal free
    Yes
    Mercury free
    Yes
    RoHS exemption information
    China RoHS Regulation
    Environmental Disclosure
    Circularity Profile
    WEEE
    The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
    Contractual warranty
    Warranty
    18 months
  • View more View less

    Documents

    Language
    • All Languages13
    • English13
    • Chinese4
    • French4
    • German4
    Catalogue
    Format
    Size
    Date
    Add to My Documents
    Instruction sheet
    Format
    Size
    Date
    Add to My Documents
    CAD
    Format
    Size
    Date
    Add to My Documents
    CAD for XPSABV1133C: module XPSABV - stop and switch monitoring - 24 V AC/DC (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    CAD for XPSABV1133C: module XPSABV - stop and switch monitoring - 24 V AC/DC (Version 1.0)
    Description
    You will be redirected to the ThomasNet website. Then you could download this CAD model in more than 15 different 2D or 3D CAD formats.
    Certificate
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 11.2 MB
    Date 23/04/19
    Size pdf
    Size 613.6 KB
    Date 06/12/17
    Declaration of conformity
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 530.8 KB
    Date 12/06/18
    EU RoHS Declaration
    Format
    Size
    Date
    Add to My Documents
    module XPSABV - stop and switch monitoring - 24 V AC/DC
    Description
    module XPSABV - stop and switch monitoring - 24 V AC/DC
    Size pdf
    Size 195.3 KB
    Date 20/11/19
    Description
    module XPSABV - stop and switch monitoring - 24 V AC/DC
    Product Environmental Profile
    Format
    Size
    Date
    Add to My Documents
    Size pdf
    Size 2.2 MB
    Date 01/05/18
    REACh Declaration
    Format
    Size
    Date
    Add to My Documents
    module XPSABV - stop and switch monitoring - 24 V AC/DC
    Description
    module XPSABV - stop and switch monitoring - 24 V AC/DC
    Size pdf
    Size 195.3 KB
    Date 20/11/19
    Description
    module XPSABV - stop and switch monitoring - 24 V AC/DC
    RoHs China Declaration
    Format
    Size
    Date
    Add to My Documents
    module XPSABV - stop and switch monitoring - 24 V AC/DC
    Description
    module XPSABV - stop and switch monitoring - 24 V AC/DC
    Size pdf
    Size 195.3 KB
    Date 20/11/19
    Description
    module XPSABV - stop and switch monitoring - 24 V AC/DC
  • Technical FAQs

    No results found.
    Unfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.
  • Dimensions Drawings

    Dimensions



Compare products: /