T568B Color Code
RJ45 Pin---Pair Color
1-------------White/Orange
2-------------Orange
3-------------White/Green
4-------------Blue
5-------------White/Blue
6-------------Green
7-------------White/Brown
8-------------Brown
T568A Color Code
RJ45 Pin---Pair Color
1-------------White/Green
2-------------Green
3-------------White/Orange
4-------------Blue
5-------------White/Blue
6-------------Orange
7-------------White/Brown
8-------------Brown