Reference Design 121

Reference Design 121 10.4 MW Greenfield / 6.2 MW Retrofit, AMD Instinct™ MI455X, AMD Helios Rack Scale Solution, 246 kW/rack, Tier III AI infrastructure.Reference Design 89

Reference Design 89 3.72 MW, Tier III, IEC, Chilled Water, Liquid-Cooled AI Clusters (NVIDIA B300).Controls Reference Design 2

Controls Reference Design 2 Based on EcoStruxure Operation. Complements NVIDIA GB200, GB300, Vera Rubin reference designs.Reference Design 113

Reference Design 113 10MW-12.4 MW, NVIDIA Vera Rubin NVL72, Tier 3, chilled water, liquid-cooled AI clusters, 37,774 square feet.Controls Reference Design 1

Controls Reference Design 1 Based on Aveva™ System Platform. Complements NVIDIA GB200, GB300 reference designs.Reference Design 111

Reference Design 111 7536 kW, NVIDIA GB300 NVL72, Tier 3, chilled water, liquid-cooled AI clusters, 3,508 square metres.Reference Design 110

Reference Design 110 7536 kW, NVIDIA GB300 NVL72, Tier 3, chilled water, liquid-cooled AI clusters, 3,424 square metres.Reference Design 109

Reference Design 109 7392 kW, NVIDIA GB200 NVL72, Tier 3, chilled water, liquid-cooled AI clusters, 3,508 square metres.Reference Design 108

Reference Design 108 7392 kW, NVIDIA GB200 NVL72, Tier 3, chilled water, liquid-cooled AI clusters, 3,424 square metres.Reference Design 47

Reference Design 47 1000 kW, 12 racks, ANSI, liquid-cooled and air-cooled, modular all-in-one AI solution.Reference Design 48

Reference Design 48 1000 kW, 12 racks, IEC, liquid-cooled and air-cooled, modular all-in-one AI solution.Reference Design 100

Reference Design 100 3818 kW, Tier 3, chilled water, liquid-cooled, and air-cooled AI clusters, 3,059 square metres.
Accelerate AI factory design with proven infrastructure blueprints
Enable AI infrastructure design by building new AI factories or retrofitting existing data centres with fully engineered, validated infrastructure blueprints. Leverage NVIDIA‑collaborated architectures to reduce risk, speed deployment, and scale AI with confidence.

What are AI data centre reference designs?
What are AI data centre reference designs?
Starting point for data centre design
A data centre reference design is a pre‑validated, fully engineered blueprint that defines how power, cooling, and IT infrastructure should be organised to build a reliable, scalable, and AI‑ready data centre.
- Uses proven, standardised layouts.
- Ensures infrastructure compatibility.
- Reduces risk during deployment.
- Supports AI workloads.
- Enables faster data centre site build-outs.
Working closely with all the leading GPU, TPU, server manufactures, and integrators, we continue to expand our library of fully engineered reference designs to address the fast pace and change the industry is experience. AI demands more 'reference designs' we deliver.

Explore our reference designs
Access each reference design's design summary PDF to view a detailed overview of the offer.
Frequently Asked Questions
Newest reference designs
Controls reference design
Explore the controls reference design that complements NVIDIA GB200, GB300, and Vera Rubin NVL72‑based architectures, supporting high‑density, AI‑ready data centre deployments.

AI liquid cooling design
Collaborating with NVIDIA, we deliver validated AI reference designs supporting high‑density, liquid‑cooled clusters. Explore full‑facility architectures for GB300 and NVL72‑based deployments.

Modular data centre AI reference design
Modular data centre solutions address the needs of both hyperscale and edge use cases to handle the AI revolution. They provide the infrastructure, electrical power, and cooling necessary to achieve strategic AI goals.

Explore additional resources
White papers
Calculators
Library of trade-off tools

Explore our library of trade-off tools to explore design choices.
CapEx calculator

Estimate capital cost of data centres.
PUE calculator

Estimate how various design decisions impact efficiency of data centre.
Temperature rise calculator

Estimate temperature rise after primary power loss.
Explore the full AI factory portfolio
AI factory
From grid-to-chip, chip-to-chiller, for scalable AI.
Simulate
OpenUSD digital twins with ETAP and NVIDIA Omniverse for AI infrastructure modelling.
Power
800 VDC architectures, rack-level power, and resilient energy distribution.
Liquid cooling
Direct-to-chip, immersion, and hybrid cooling for high-density AI workloads.
Prefab
Modular pods and white-space modules (time-to-ready).
Software
DCIM, planning/modelling, alarm management, OT cybersecurity.
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales enquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Centre
Find support resources for all your needs, in one place.