How to import SoMachine/Machine Expert - Basic symbols in Vijeo Designer?
- First you need to export your project as "SoMachine Basic project" (see attachment 1)
- Second in Vijeo designer:
- Add in the IO Manager a Modbus TCP/IP Drive and select Modbus Equipment
- Write the IP Address of the M221 PLC and check the case IEC61131. Also you need to select the Double word order. (see attachment 2)
- Do a right click in the "Variables”, select "Link Variables", select type files "*.SMPB" and then select your project (see attachment 3)
- Now you can select witch symbols do you want to import
Using SoMachine/Machine Expert - Basic standalone
In Vijeo designer:
- Add in the IO Manager a Modbus TCP/IP Drive and select Modbus Equipment
- Write the IP Address of the M221 PLC and check the case IEC61131. Also you need to select the Double word order. (see attachment 2)
- Do a right click in the "Variables”, select "Link Variables", select type files "*.SMPB" and then select your project (see attachment 3)
- Now you can select witch symbols do you want to import