Configuration Manager Tool 2020 - Unable to Write to System - PME Portuguese Language
"Write to System" is grayed out when trying to write an archive from a "PME 2020 - language Portuguese" into a new "PME 2020 - language Portuguese" - regardless if it is distributed or standalone.
Product Line
Power Monitoring Expert 2020
Environment
Configuration Manager Tool 2020 (CM Tool 2020) - System Migration PME 2020 to PME 2020
Cause
The registry CultureInfoName in a PME system for Portuguese version is set to "pt-BR" however CMTool file that reads the supported versions is using "pt", hence the tool cannot recognize this as a supported path.
Resolution
- Open Configuration Manager Tool 2020 > bin > SupportedVersions.xml in a notepad (make a copy of this file just for safety).
- Search for Languages="pt"
- You will find 4 lines:
- Line 189: <From Version="9.1" InstallationTypes="Distributed" Languages="pt" Editions="" />
- Line 190: <To Version="9.1" InstallationTypes="Distributed" Languages="pt" Editions="" />
- Line 237: <From Version="9.1" InstallationTypes="Standalone,Distributed" Languages="pt" Editions="" />
- Line 238: <To Version="9.1" InstallationTypes="Standalone,Distributed" Languages="pt" Editions="" />
- Replace it for Languages="pt-BR"
- Save it.
Gepubliceerd voor: Schneider Electric Belgium


Hulp nodig?
Selecteer zelf het juiste product
Vind snel en eenvoudig de juiste producten en toebehoren voor uw toepassingen.
Offerte aanvragen
Dien uw aanvraag online in en een expert zal contact met u opnemen.
Verkooppunten
Vind eenvoudig de dichtstbijzijnde distributeur van Schneider Electric op uw locatie.
Help Center
Vind de antwoorden die u nodig heeft via bladeren door veelgestelde vragen over onderwerpen.