Issue:
Is sensorless flux vector available on the ATV61 and ATV71 drives?
Product Line:
Alitvar ATV61 and ATV7
Environment:
All
Cause:
motor control type
Resolution:
Yes, They both have this feature you can access it in Menu 1.4 motor control type and find SVC V.
SVC-V is open loop voltage flux vector control. It supports operation with a number of motors connected in parallel on the same drive.
This is the default motor control setting on the ATV71 drive and it can be changed to on the ATV61 drives.
Udgivet til: Schneider Electric Danmark




Brug for hjælp?
Produktvælger
Find hurtigt og nemt de rette produkter og det rette tilbehør til dine anvendelser.
Få et tilbud
Start din salgsforespørgsel online, så vil du blive kontaktet af en ekspert.
Find forhandler
Find den nærmeste Schneider Electric-distributør.
Hjælpecenter
Find supportressourcer til alle dine behov på ét sted.