Issue:
Temperature of an ATV61 or ATV71 series drive
Product Line:
ATV61 and ATV71series drives
Environment:
All models, all serial numbers
Cause:
Information is not available in current literature.
Resolution:
The "Drive thermal state" can be read though the monitoring menu on the keypad. This will not tell you the actual temperature of the drive, but it will tell you the percentage of temperature based on normal operating temperature of the drive.
Also, you can read this temperature via the serial communication network at logic address 14114, 16#3722. This is an unsigned integer between 1 and 118. If the drive thermal state reaches 118%, the drive will shut down with a detected fault of "DRIVE OVERHEAT"
Temperature of an ATV61 or ATV71 series drive
Product Line:
ATV61 and ATV71series drives
Environment:
All models, all serial numbers
Cause:
Information is not available in current literature.
Resolution:
The "Drive thermal state" can be read though the monitoring menu on the keypad. This will not tell you the actual temperature of the drive, but it will tell you the percentage of temperature based on normal operating temperature of the drive.
Also, you can read this temperature via the serial communication network at logic address 14114, 16#3722. This is an unsigned integer between 1 and 118. If the drive thermal state reaches 118%, the drive will shut down with a detected fault of "DRIVE OVERHEAT"
Udgivet til: Schneider Electric Danmark






Brug for hjælp?
Produktvælger
Find hurtigt og nemt de rette produkter og det rette tilbehør til dine anvendelser.
Få et tilbud
Start din salgsforespørgsel online, så vil du blive kontaktet af en ekspert.
Find forhandler
Find den nærmeste Schneider Electric-distributør.
Hjælpecenter
Find supportressourcer til alle dine behov på ét sted.