RealFLO and ClearSCADA Cross-Compatibility

The following table shows the compatibility between RealFLO flow computer versions and ClearSCADA versions.



ClearSCADA VersionBuild NumberRealFLO Version Number
<5.20<6.00>=6.00>=6.70>=6.71>=6.73>=6.79
2013 R274.5094
2013 R2.174.5192
2013 R2.274.5700
2014 R175.5210Non      16-bit onlyNon        16-bit only
2014 R1.175.5387
2015 R176.5648
2015 R277.5882
2017 R178.6284
2017 R279.6697
2017 R380.6914



ClearSCADA VersionBuild NumberRealFLO Version Number
>=6.80>=6.81>=6.90>=6.91>=6.93>=6.95>=6.96
2013 R274.5094
2013 R2.174.5192
2013 R2.274.5700
2014 R175.5210
2014 R1.175.5387Non      16-bit onlyNon      16-bit onlyNon      16-bit only
2015 R176.5648Non      16-bit onlyNon      16-bit onlyNon      16-bit onlyNon      16-bit only
2015 R277.5882
2017 R178.6284
2017 R279.6697
2017 R380.6914



ClearSCADA VersionBuild Number>6.70 (Note 1)>6.82 (Note 2)>6.70 (Note 3)
2013 R274.5094
2013 R2.174.5192
2013 R2.274.5700
2014 R175.5210
2014 R1.175.5387Hotfix 75.5568.1Non 16-bit only
2015 R176.5648Non 16-bit onlyHotfix 76.5745.1Non 16-bit only
2015 R277.5882Hotfix 77.6807
2017 R178.6284
2017 R279.6697
2017 R380.6914



Key
ClearSCADA Version does not work with the version of RealFLO
ClearSCADA Version does not work with the version of RealFLO – Hotfix is available
ClearSCADA works with this version
ClearSCADA works with this version but not all RealFLO features can be configured
Note 1The following 16-bit controllers have had their features frozen to flow computer version 6.70 features: Micro16, SCADAPack, SCADAPack Light, SCADAPack Plus, SCADAPack LP and SCADAPack 100
Note 2The following 32-bit controllers have had their features frozen to flow computer version 6.82 features: SCADAPack32 and SCADAPack32P
Note 3For ClearSCADA 2014 R1.1, ClearSCADA 2015 R1 and ClearSCADA 2015 R2, support for flow computers newer than version 6.70 is not supported in 16-bit controllers.

ClearSCADA 2015 R2 version 77.6807 will work with flow computers newer than version 6.70 (in 16-bit controllers) but the features will be frozen to flow computer version 6.70

Schneider Electric Danmark

Se mere
Område:
Se mere
Område:

Brug for hjælp?

  • Produktvælger

    Find hurtigt og nemt de rette produkter og det rette tilbehør til dine anvendelser.

  • Få et tilbud

    Start din salgsforespørgsel online, så vil du blive kontaktet af en ekspert.

  • Find forhandler

    Find den nærmeste Schneider Electric-distributør.

  • Hjælpecenter

    Find supportressourcer til alle dine behov på ét sted.

  • Produktdokumentation
  • Download af software
  • Produktvælger
  • Udskiftning og erstatning af produkter
  • Hjælp og kontaktcenter
  • Find forhandler
  • Få et tilbud
  • Find vores kontorer
  • Karriere
  • Virksomhedsprofil
  • Rapportér en forseelse
  • Tilgængelighed
  • Presserum
  • Investorer
  • EcoStruxure
  • Jobsøgning
  • Blog
  • Privatlivspolitik
  • Cookiemeddelelse
  • Vilkår for anvendelse
  • Rediger dine cookieindstillinger