Issue:
Setting deceleration time on a ATV320.
Product Line:
ATV320
Resolution:
Parameters described in this page can be accessed by: DRI- > CONF > FULL > SIM
Goto Configuration Mode (ConF) > Enter
Goto to FULL > Enter
Goto SIM > > Enter
Goto deC [Deceleration] default 3.0s
Set desired value for deceleration time.