Hvordan kan vi hjælpe dig i dag?

Why does my Connexium switch not capture VLAN tags using mirror port ?

This behavior is a limitation of the Connexium switch range. Connexium switches cannot mirror Ethernet frames while preserving the original VLAN tags.

For applications requiring VLAN information during packet capture, the Modicon switch range provides enhanced port-mirroring behavior.

According to the Modicon switch documentation for the Primary port (destination port):

“On the destination port, the device adds a VLAN tag to the data packets that the source port transmits. The destination port transmits unmodified the data packets that the source port receives.”

This behavior allows VLAN information to be available on the destination port used for traffic analysis.

Schneider Electric Danmark

Se mere

Se mere

Brug for hjælp?

Produktvælger

Find hurtigt og nemt de rette produkter og det rette tilbehør til dine anvendelser.

Få et tilbud

Start din salgsforespørgsel online, så vil du blive kontaktet af en ekspert.

Find forhandler

Find den nærmeste Schneider Electric-distributør.

Hjælpecenter

Find supportressourcer til alle dine behov på ét sted.