Workaround to access Data Quality Reports when encountering out-of-memory errors

Issue Description:

After running analysis, attempting to access the report tab within the Data Quality (DQ) tab results in the page failing to load. Subsequently, the browser throws an out-of-memory exception error.

Product Line:

Power Advisor

Cause:

The root cause of the issue is the large size of certain sites, which includes thousands of devices. This leads to a memory crash in the browser when attempting to load one month of data.

Resolution:

Workaround to Generate the Data Quality (DQ) Report

If you encounter issues generating the DQ report due to a memory crash, follow these steps:

  1. Generate a DQ Report from a Smaller Site:

2. Retrieve the Analysis Result ID from the Problematic Site:

  • On the problematic site, open Chrome Developer Tools (F12).
  • Run the analysis and navigate to the DQ tab.
  • In the Network tab, search for 'analysisResultId' and record the value.
    AnalysisResultID

3. Access the DQ Report:

Schneider Electric Danmark

Se mere
Område:
Se mere
Område:
  • Produktdokumentation
  • Download af software
  • Produktvælger
  • Udskiftning og erstatning af produkter
  • Hjælp og kontaktcenter
  • Find forhandler
  • Få et tilbud
  • Find vores kontorer
  • Schneider Electric Community
  • Karriere
  • Virksomhedsprofil
  • Rapportér en forseelse
  • Tilgængelighed
  • Presserum
  • Investorer
  • EcoStruxure
  • Jobsøgning
  • Blog
  • Privatlivspolitik
  • Cookiemeddelelse
  • Vilkår for anvendelse
  • Rediger dine cookieindstillinger