Why do I get an error when configuring port mirroring across certain ports on an MCSESM203F4LG0 switch?
Why do I get an error when configuring port mirroring across certain ports on an MCSESM203F4LG0 switch, and how can I enable mirroring?
Answer:
-
Issue
Configuring port mirroring on MCSESM203F4LG0 fails with error message: "TX mirroring across unit boundaries is not supported" -
Product Line
- Hardware: MCSESM203F4LG0
- Software Version (SV): 8.7.10
-
Resolution
Port mirroring on this model is limited to a single switching chip. Mirroring across the two internal chips is not supported—this is a hardware limitation.
The MCSESM203F4LG0 has two internal switching chips:
- Chip 1: Ports 1/1 to 1/12
- Chip 2: Ports 1/13 to 1/20
To resolve:
- Ensure that the mirror destination (primary/monitor port) and all mirror source ports (TX/RX) are on the same chip.
- Example: Choose the monitor port from 1/1–1/12 and only select mirror sources within 1/1–1/12; do not include ports from the other chip.
-
FAQ Applicable Conditions
- This FAQ remains valid unless a new hardware revision explicitly adds cross-chip mirror support.
Udgivet til: Schneider Electric Danmark
Brug for hjælp?
Produktvælger
Find hurtigt og nemt de rette produkter og det rette tilbehør til dine anvendelser.
Få et tilbud
Start din salgsforespørgsel online, så vil du blive kontaktet af en ekspert.
Find forhandler
Find den nærmeste Schneider Electric-distributør.
Hjælpecenter
Find supportressourcer til alle dine behov på ét sted.