Symmetra PX
High-performance, right-sized, modular, scalable 3 phase UPS (10-100 kW 208V, 100-500 kW 480V, 16-500 kW 400V) for any size data center or facility
Produkter
Præsentation
Fordele
Agility
- Scalable power capacity - Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
- SmartSlot - Customize UPS capabilities with management cards.
- Programmable frequency - Ensures compatibility with different input frequencies.
- Swappable power modules - Allows quick addition of power capacity or replacement of existing power modules. Installed modules are automatically recognized by the system.
- Power Modules connected in parallel - Enhances availability by allowing immediate, seamless recovery from isolated module failures.
- Redundant Intelligence Modules - Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
- Configurable for N+1 internal redundancy - Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
- Automatic internal bypass - Supplies utility power to the connected loads in the event of a UPS power overload or fault.
- Network manageable - Provides remote power management of the UPS over the network.
- Modular design - Provides scalability, N+1 redundancy, fast serviceability, and reduced maintenance requirements via self-diagnosing, hot-swappable, and field-replaceable modules.
- Audible alarms - Provides notification of changing utility power and UPS power conditions
- LED status indicators - Quickly understand unit and power status with visual indicators.
- Integrates with StruxureWare Data Center Expert - An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
- EU CoC for UPS - Ensures that UPSs sold in the EU are highly efficient
- Input Power Factor Correction - Minimizes installation costs by enabling the use of smaller generators and cabling.
- Fully-rated power kVA equals kW - Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
- 5x8 Start-up service included - Required for full coverage of factory warranty
- Generator compatible - Ensures clean, uninterrupted power to protected equipment when generator power is used.
- User-replaceable power modules - Enables simple upgrades and replacements of the Power Modules.
- Battery modules connected in parallel - Delivers higher availability through redundant batteries.
- User-replaceable batteries - Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)