XPS-CE Replaced by XPS-CM
XPSCE (older model) XPSCM (newer model)- XPS-CM has 3 extra solid state outputs for PLC signalling
- XPS-CM has choice between 2 models with or without removable plug terminals (P)
- XPS-CM has muting lamp error detection
- XPS-CM has only one muting lamp connection
- XPS-CM uses 4 muting sensors
Schematic Comparisons
Monitoring of 4 XU2-S single beam detectors with muting function
Cross Reference Table
NOTE: Data sheets about new safety relays XPSCM are available on the website to download, use the search engine (top right corner)