브랜드

슈나이더 일렉트릭 코리아 웹사이트에 방문해 주셔서 감사합니다.

슈나이더 일렉트릭 코리아 웹사이트 방문자 분들 모두 환영합니다.
		
오늘 무엇을 도와드릴까요?
Why am I getting ": "Warning, application has halted due to : cannot find empty slot to insert error message file KAOScore.txt KAOScore:portable.error.cpp : line 221" and how to resolve the issue?

Issue:
Why am I getting ": "Warning, application has halted due to : cannot find empty slot to insert error message file KAOScore.txt KAOScore:portable.error.cpp : line 221" and how to resolve the issue?

Product Line:
Vijeo Designer

Resolution:
This error is essentially related to the low level error handling system of Vijeo Designer Runtime.
KAOScore.txt is one of several files containing error messages. When an error occurs, Runtime inserts this file into a buffer in order to load the error message.

The error reported occurs when this buffer has somehow become full and Runtime cannot insert any more files.
In theory, this should not happen because there are more slots than there are files.

If there is an ERRORLOG.txt file in the customer's target, it might give us more information as to how the buffer ran out of slots.

But rebooting the target cleans out the buffer and will boot up back to normal. If this does not work, please uninstall and re-install the runtime and reload the program file.

If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.

If you are not located in North America, please contact your local Customer Care Center for assistance:

Support | Schneider Electric Global (se.com)

슈나이더 일렉트릭 Korea

자세히 알아보기
제품군
자세히 알아보기
제품군
  • 제품 문서
  • 소프트웨어 다운로드
  • 제품 선택기
  • 제품 대체 및 교체
  • 지원 및 연락처 센터
  • 영업소 검색
  • 견적 받기
  • 슈나이더 일렉트릭 커뮤니티
  • 채용
  • 회사 소개
  • 부정 행위 보고
  • 접근성
  • 뉴스룸
  • 투자자
  • Ecostruxure
  • 작업 검색
  • 블로그
  • 개인정보 취급방침
  • 쿠키 공지
  • 사용 약관
  • Change your cookie settings