Чем мы можем помочь сегодня?
Where can I find the Compatibility Support Matrix for PowerLogic/ION products?
Issue:
Identify supported operating systems, browser support and key upgrade/security notes for the most recent releases of EcoStruxure™ Power Monitoring Expert (PME), and provide legacy references for older versions.
Product Line:
Power Monitoring Expert 9.0
Power Monitoring Expert 2020
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023
Power Monitoring Expert 2024
Environment:
New installations and upgrades of PME application servers, engineering clients, and distributed database architectures.
Summary Report Packs
Event Notification Module
Active Pager Module
Sequence of Events Recorder
Resolution (Summary of Current Status):
PME 2024 R3 (Current)
Supported Operating Systems (High Level)
| Category | Supported Editions |
| Windows Server | 2025 Standard/Datacenter (Application Server); 2022 Standard/Datacenter LTSC; 2019 Standard/Datacenter LTSC; 2016 Standard LTSC |
| Windows (Client/IoT) | Windows 11 Enterprise LTSC; Windows 11 IoT Enterprise LTSC; Windows 10 Enterprise LTSC; Windows 10 IoT Enterprise LTSC |
Note: For the complete and authoritative list (including exact build numbers and any role limitations), see the PME 2024 IT Guide and System Guide.
Browser Support (Web Applications)
| Browser | Support |
| Microsoft Edge (Chromium) | Supported (current) |
| Google Chrome | Supported (current) |
| Mozilla Firefox | Supported (current) |
Note: Detailed browser/version specifics are maintained in the PME 2024 Web Application Guide.
PME 2023 (Transitional)
For customers on PME 2023, consult the online System Guide and install/upgrade topics for OS/SQL specifics. Upgrade to PME 2024 R3 is recommended for newest OS support and security fixes.
Legacy Releases (Reference Only)
The following information is retained for reference. These versions are in Limited or Mature support; upgrading to a current release is recommended.
Power Monitoring Expert 2020 – Operating Systems
| Operating Systems |
| Windows 10 Professional/Enterprise |
| Windows Server 2012 R2 Standard/Enterprise |
| Windows Server 2016 Standard |
| Windows Server 2019 Standard |
Power Monitoring Expert 2020 – SQL Server Editions
| SQL Server Edition | Standalone Server | Distributed Database Server |
| SQL Server 2012 Express | Yes | |
| SQL Server 2014 Express | Yes | |
| SQL Server 2016 Express | Yes | |
| SQL Server 2017 Express | Yes | |
| SQL Server 2012 Standard/Enterprise/BI | Yes | Yes |
| SQL Server 2014 Standard/Enterprise/BI | Yes | Yes |
| SQL Server 2016 Standard/Enterprise/BI | Yes | Yes |
| SQL Server 2017 Standard/Enterprise/BI | Yes | Yes |
Note: Supported 32-bit/64-bit SQL editions must match the OS (32-bit SQL is not supported on 64-bit Windows).
PME 9.0 Compatibility Details
The following table lists supported Operating Systems and SQL Server versions for PME 9.0, following the same format as PME 2020.
| Component | Supported Versions | Notes |
| Operating System | Windows Server 2016 (Standard, Datacenter) | 64-bit only |
| SQL Server | SQL Server 2016 SP2 (Standard, Enterprise) | 64-bit only |
| Browser | Microsoft Edge | Latest versions recommended |
Note that supported 32-bit and 64-bit SQL Server editions can only be installed on supported 32-bit and 64-bit Windows operating systems, respectively. For example, a 32-bit SQL Server edition is not supported on a 64-bit Windows operating system.
Recommendation:
If you are using an older version of PME, consider upgrading to the latest version for improved protocol support and security. For assistance with integration or upgrades, contact Schneider Electric Technical Support at: pmo.support@se.com
Опубликовано для: Schneider Electric Казахстан
Узнайте больше
Линейка:
Узнайте больше
Линейка:
Нужна помощь?
Инструмент для подбора продукции
Быстро и легко находите подходящие продукты и принадлежности для ваших условий применения.
Получить коммерческое предложение
Заполните заявку онлайн, и с вами свяжется наш эксперт.
Где купить?
Легко находите ближайшего к вам дистрибьютора Schneider Electric.
Центр поддержки
Находите ресурсы поддержки для всех ваших потребностей в одном месте.