Does the ATV312 have Brake Logic Control?
Issue:
Can I set up Brake Logic Control on the ATV312?
Product line:
Altivar ATV312
Environment:
All models, all serial numbers
Cause:
Customer wanted to use brake logic control function.
Resolution:
The ATV312 does have a Brake Logic Control function. This enables the drive to manage an electromagnetic brake.
To program it, go to menu FUN, then sub-menu bLC-, then bLC (brake assignment).
See attachment, excerpt from the program manual.