AccuSine PFV+

The Schneider Electric solution for electronic reactive current compensation for specific and high performance solutions.

Part of PowerLogic

AccuSine PFV+ is a very simple and effective means to eliminate leading or lagging power factor, reduce voltage fluctuations enhance equipment operating life, and improve system power capacity. AccuSine PFV+ offers many features in one package that others require multiple models to accomplish. Power Factor correction with AccuSine PFV+ is worry-free and without the risk of resonance.

AccuSine PFV+
  • Features

    AccuSine PVF+ can be operated as a displacement power factor correction and/or load balancing device.

    Technical Data
    Standard RMS output current ratings


    • 60 A, 120 A, 200 A, 300 A - 380 V AC to 480 V AC
    • 47 A, 94 A, 157 A, 235 A - 480-600 V AC
    • 40 A, 80 A, 133 A, 200 A - 600-690 V AC
    Nominal voltage

    • 380-480 V AC; +10%/-15%
    • 480-600 V AC; +10%/-15%
    • 600-690 V AC; +10%/-15%
    Up to 35kV with external transformers.

    Nominal Frequency

    • 50/60 Hz, ±3 % auto sensing
    Power factor correction

    • Optimized unity PF, Leading (capacitive) or lagging (inductive) power factor (Cos f) to target.
    Mains current balancing

    • Negative sequence current injected to balance fundamental current on the mains due to load imbalance (inherently corrects displacement PF (Cos φ)).
    Control response time

    • 25 μs
    Reactive correction time

    • 1/4 cycle
    Operating Temperature 

    • 60 A, 120 A & 200 A: IP00, IP20, UL Type Open, & UL Type 1 configurations -0 °C to 45 °C
    • All others 0 °C to 40 °C
    • Derate 2 % per degree °C to 50 °C
    Relative humidity

    • 0-95 %, noncondensing
    Operating Altitude

    • 1000 m (derate 1 %/100 m above)
    Standards compliance/certification

    • cULus (UL508 , CSA 22.2 No. 14)
    • CE Certified, ABS, Lloyds, other local standards
    Display

    • 145 mm QVGA TFT 7-color touchscreen
    HMI (Magelis STU)

    • Plain language output (no cryptic codes)
    Protection (enclosure)

    • IP00, IP20, IP31, IP54, UL Type 2, UL Type 12
     

    What is power quality?
    In an ideal three phase power system, voltages are at nominal magnitude and frequency, perfectly balanced and with a perfect sinusoidal waveform. Any disturbance on one parameter (magnitude, frequency, waveform, or symmetry) is classified as a power quality issue. There are a variety of power quality disturbances – voltage dips, harmonics, transients, etc. – all of which can have negative impacts on the electrical system and equipment, such as power outage, device damage, failure, overheating, degraded performance and reduced equipment life.

    AccuSine PFV+ stops power quality issues like voltage sags and flicker due to load current fluctuations (VAR compensation). For larger power quality applications, AccuSine PFV+ can be combined with a capacitor bank to reduce system cost. It can add or subtract to the capacitor bank output, achieving high speed reactive compensation with infinite resolution. It also provides high speed Powoer Factor correction where traditional capacitor banks are unable to track loads.



    Benefits


    • Flexible and scalable
    • Peace of mind:
    • Worry-free power factor correction without the risk of resonance
    • Simple installation and ease of expansion
    • Flexible parallel operation modes for multi-unit installations 
    • Current transformers can be installed on the incoming mains (source sense) or on the feeders to the loads (load sense) for maximum installation flexibility  

    Applications

     

    • Stop voltage sags and flicker due to load current fluctuations (VAR compensation): Ball mills, shredders, arc welders, arc furnaces, hard to start AC motors, and more.
    • Correction of leading power factors in data centers to allow back-up generators to operate.
    • High speed power factor correction where traditional capacitor banks are unable to track loads.
    • For larger applications AccuSine PFV can be combined with a capacitor bank to reduce the system cost. AccuSine PFV can either add or subtract to the capacitor bank output to achieve an high speed reactive compensation system with infinite resolution. 