What are the separate parts required to build up star delta starters for...

The table below indicates the selection of the power switching components necessary to build up a star delta starters, with mechanical interlocks between star and delta contactors, suitable for...

What does a PHF fault mean on an ATV320 drive?

Product line: Altivar 320 / ATV320 Cause: Loss of input voltage on L1, L2 or L3 Resolution: Check for phase loss or phase imbalance Check the line voltage power, input connections and/or fuses Check...

Multimotor configuration ATV630

With an ATV630 it is not possible to implement a multi motor configuration with different motors. Only with equal motors it can be done with parameter set switching ( no motor parameters ! ) to make...

What is the definition of zero-sequence impedance for a three-phase...

The zero-sequence impedance is between connected together line terminals of a three-phase star-connected or zigzag-connected transformer windings and its neutral terminal. Zero-sequence impedance...

Network Management Card 3 - CDC-USB driver on Windows

Issue: When using Windows 7 and connecting a NMC3 device via USB for configuration, CDC-USB drivers might need to be updated on initial use. Product: Network Management Card 3 (AP9640, AP9641)...

What size overload do I use with a star delta starter ?

In the majority of cases, the overload of a star delta starter is fitted below the delta contactor with wiring connections to one side of each of the motor windings. The other side of the windings...

What is the difference between isolated and non-isolated coaxial sockets?...

A non-isolated coax socket is a standard socket. If you wish to install a socket to connect your TV coax lead into, this is what is required. Also, this version must be used for satellite...

Will Zelio Soft 2 V4.5 work on Windows 7 64 bit?

Yes, Zelio Soft 2 V4.5 is compatible with Windows 7 64 bit with one exception ; when communicating between the PC/Laptop and the Zelio Logic Relay, and using the USB cable SR2USB01 with Windows 7 64...

Show more
Popular Video FAQsPopular Videos
Show more
Learn more through our Generic Knowledge FAQsGeneral Knowledge
What is the difference between PNP and NPN when describing 3 wire...

Most industrial proximity sensors (inductive, capacitive, ultrasonic and photo electric) are solid state. The term solid state refers to the type of components used within the sensor. Solid state...

What size overload do I use with a star delta starter ?

In the majority of cases, the overload of a star delta starter is fitted below the delta contactor with wiring connections to one side of each of the motor windings. The other side of the windings...

Adding a new DD to your TREX

Before getting started make sure that you have Upgrade Studio installed on your laptop and that you have an account to log in. You also must have already activated your TREX communicator. Go to...

How can I cable to the PNP and NPN type outputs for sensors / detectors,...

PNP and NPN type outputs are available as 3-wire sensors with a DC voltage power supply (the voltage limits are dependent on the specific sensor): PNP type: switching on the positive voltage load NPN...

How do you calculate the wear level of TeSys Giga contactor ? By...

Contact tips wear rate of is linked to the opening speed and not the opening time. Our algorithm is based on this concept with a dedicated electronic circuit. Arc Voltage is a function of contact...

What are the differences between snap-action and slow-break contacts in...

Note we no longer sell limit switches so the information given below is for information purposes only. You may still be able to buy Telemecanique limit switches (and some 9007 etc. ex-Schneider...

Show more

Need help?

  • Get a Quote

    Start your sales inquiry online and an expert will connect with you.

  • Where to buy?

    Easily find the nearest Schneider Electric distributor in your location.

  • Help Center

    Find support resources for all your needs, in one place.

  • Products Documentation
  • Software Downloads
  • Product Substitution and Replacement
  • Help and Contact Center
  • Find our Offices
  • Get a Quote
  • Where to buy
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings