Acti9 indication and tripping auxiliaries
For Acti9 MCBs, RCDs, switches, remote control, automatic reclosers, etc.
Features
With exclusive features, Acti 9 iC60 DIN rail electrical auxiliaries are definitely geared to absolute safety.
- VISI-TRIP: to detect faulty outgoers quickly and reduce intervention time.
- Clip-on assembly system
- iOF: Auxiliaries for remote indication of the state of the device to which they are connected (compliance with IEC 60947-5-1)
- Remote indication of "open" or "closed" state
- Remote indication of "tripped" state
- For more information click here - Auxiliaries for remote tripping of the device to which they are connected (compliance with IEC 60947-1)
- Instantaneous tripping when the control circuit is energized
- Instantaneous tripping when the control circuit is de-energized or if there is a dip in its supply voltage
- Time-delayed tripping (to cope with micro-breaks or brief voltage drops) when the control circuit is de-energized or if there is a dip in its supply voltage
- Fail-safe emergency stop tripping <
- Overvoltage tripping
- For more information click here - Auxiliary RCA for remote Control
- Remote electrical control (opening and closing) of circuit breakers with or without Vigi iC60 add-on RCD, with or without auxiliary.
- Circuit-breaker resetting after tripping, in accordance with safety principles and the regulations in force.
- Local control by operating handle.
- For more information click here - Auxiliary ARA for remote Automatic Reclosing
- Perform automatic reclosing of the associated protection device, after tripping.
- Increase the availability of installations without supervision, isolated, hard of access and demanding very great availability (mobile telephony systems, motorways, pumping stations, airports, railways, meteorological stations, service stations, automatic teller machines, public lighting, tunnels, etc.), by restoring them to operation without intervention by personnel in the event of a transient fault (atmospheric disturbances, industrial overvoltages, etc.).
- For more information click here
Benefits
Offering several combinations between electrical auxiliaries and total simplicity when it comes to installation, the Acti9 iC60 DIN rail tripping auxiliaries with remote indication provide you with a clear and efficient solution.
- Simple: Features the same electrical auxiliaries for Acti9 iC60 MCBs and Acti9 iID RCCBs for total ease of use.
- Straightforward: Mechanical clip-on assembly system provides unrivalled installation simplicity.
- Smart: Offers multiple mix combinations between electrical auxiliaries: Acti9 iOF + iSD, iOF/SD + iMX, iOF + iMN, etc.
Applications
Ideally suited to electrical circuits in all industrial and commercial buildings, the iC60 DIN rail tripping auxiliaries allow for automatic reclosing, remote control, remote indication and tripping. Use for enhanced protection when working on tripped circuits caused by:
- Short-circuit current.
- Overload current.
- Earth fault leakage current.
- Undervoltage.
- Manual safety tripping action.