(window.BOOMR_mq=window.BOOMR_mq||[]).push(["addVar",{"rua.upush":"false","rua.cpush":"false","rua.upre":"false","rua.cpre":"false","rua.uprl":"false","rua.cprl":"false","rua.cprf":"false","rua.trans":"","rua.cook":"false","rua.ims":"false","rua.ufprl":"false","rua.cfprl":"false","rua.isuxp":"false","rua.texp":"norulematch","rua.ceh":"false","rua.ueh":"false","rua.ieh.st":"0"}]);

Schneider Electric Maintenance

The Schneider Electric site you are trying to view is currently under maintenance.
We apologize for the inconvenience caused. We will be back shortly.
Thank you for your patience.



" landing-cards-prop="{"getGk":[{"Title":"Kakšna je razlika med PNP in NPN pri opisu 3-žične povezave senzorja?","UrlName":"FAQ000265601","LastModifiedDate":"28/05/2024","products":"Modicon M580, Modicon M221, Modicon M241, Modicon M262","score":1.5,"firstpublisheddate":"04/03/2024","answer":"Večina industrijskih senzorjev (induktivni, kapacitivni, ultrazvočni in fotoelektrični senzorji) je polprevodniških.

Izraz polprevodniški se nanaša na vrsto komponent, uporabljenih v senzorju. Polprevodniške elektronske komponente, kot so tranzistorji, se uporabljajo za preklop izhoda senzorja ob zaznavi predmeta.

Na voljo sta dve posebni vrsti trižilnih senzorjev: PNP in NPN. Razlika je v zasnovi notranjega tokokroga in vrste uporabljenih tranzistorjev. Za preprosto razlago obeh si oglej priloženi dokument.

Ključno je, da PNP in NPN nimata nič skupnega s tem, ali je senzor normalno odprt (N/O) ali normalno zaprt (N/C), tj. senzor PNP je lahko N/O ali N/C, tako kot je lahko tudi senzor NPN N/O ali N/C.

Upoštevaj, da je predmet tega pogostega vprašanja povezan zlasti z ožičitvijo izhodov PNP/NPN za senzorje in ne s podrobnim razumevanjem tehnologije tranzistorjev. Za lažje razumevanje pa si oglej priloženo stran iz naše publikacije "Practical Aspects book", ki (na kratko) prikazuje terminologijo tranzistorjev in sheme tokokrogov. Dodatno učno gradivo o tranzistorjih PNP in NPN lahko najdeš na spletu iz več različnih virov. 

Zakaj dve vrsti?

Izbira senzorja PNP v primerjavi s senzorjem NPN je določena glede na tokokrog v katerem bo uporabljena naprava. Če se uporablja v običajnem relejskem krmilnem tokokrogu, je običajno mogoče uporabiti tip senzorja PNP ali NPN, kot je prikazano spodaj. Bolj običajna je uporaba senzorja PNP. 

Ožičenje
Običajni krmilni tokokrog relejskega tipa:
Prilogi Slika 1 / Slika 2

Uporaba s programabilnim logičnim krmilnikom (PLC)

Pri izbiri senzorja za uporabo s PLCjem je zelo pomembno, da se senzor ujema z vrsto vhodne kartice, ki se bo uporabljala na PLCju.
Obstajata dve vrsti vhodnih kartic, "sinking" (znane tudi kot pozitivna logika) in "source" (znane tudi kot negativna logika). Vredno je omeniti, da so izrazi "sinking" / "sourcing" in "positive" / "negative logic" v nekaterih panogah dobro znani, vendar niso običajno uporabljani termini. Zato je pomembno, da se vrsto senzorja, ki se bo uporabljal s kartico PLCja, določi na podlagi proizvajalčeve dokumentacije za PLC in/ali shemah ožičenja.

V Evropi je najpogostejša vrsta vhoda "sinking", ki se uporablja s senzorjem PNP, kot je prikazano spodaj. Danes so manj pogoste vhodne kartice "source", te so bile priljubljene v Aziji in za pravilno delovanje zahtevajo NPN tip senzorja. Številne sodobne vhodne kartice PLCjev je mogoče konfigurirati in ožičiti tako, da so lahko ali "sinking" ali "sourcing", čeprav je običajno treba vse vhode na določeni vhodni kartici konfigurirati enako. 

OPOMBA: Črtkana črta na naslednjem diagramu ni obvezna in je lahko potrebna ali pa tudi ne, odvisno od strojne opreme/nastavitve. Glavne žice, ki jih je treba upoštevati, so rdeča, črna in modra žica. 
PNP in NPN ožičenja:
Priloga Slika 3 / Slika 4"},{"Title":"Kakšne so razlike med omrežnimi napajalniki 220 VAC, 230 VAC in 240 VAC ter kakšno napetostno opremo naj uporabim?","UrlName":"FAQ000265598","LastModifiedDate":"28/05/2024","score":1.25,"firstpublisheddate":"04/03/2024","answer":"

V celinski zahodni Evropi se že vrsto let uporablja električno omrežje z nazivno napetostjo 220 VAC 50 Hz. V Združenem kraljestvu se uporablja 240 VAC 50 Hz.

Trenutno so VSE zahodnoevropske mreže razvrščene v kategorijo 230 VAC. V resnici ni napajanja 230 VAC, razen če se ga ustvari na kraju samem. 230 VAC je bil "standard", ki je bil ustvarjen med evropsko "harmonizacijo", da bi zagotovili enoten standard napetosti v Zahodni Evropi, vključno z Združenim kraljestvom in Irsko.

Čeprav bi bilo idealno imeti enotno napetost, je bilo preveč političnih, finančnih in tehničnih ovir za zmanjšanje napetosti v Združenem kraljestvu na evropsko raven ali za povečanje evropske napetosti na raven Združenega kraljestva, zato je bil ustvarjen nov standard, ki je zajemal oboje. To je bilo doseženo s spremembo toleranc prej obstoječih standardov oskrbe. Britanska napetost je postala 240 VAC + 6 % in - 10 %, evropska pa 220 VAC + 10 % in - 6 % (s čimer se je ustvarilo obvladljivo prekrivanje), ti dve kombinaciji pa smo poimenovali 230 VAC, čeprav nihče ni namerno ustvarjal 230 VAC!

Glede na napetostno občutljivost izdelka in odstopanje dejanske napajalne napetosti od nazivne, morda ni priporočljivo uporabljati naprave, ki je specifična za 220 VAC, v Združenem kraljestvu ali 240 VAC v celinski Evropi itd. napajanje 240 VAC lahko na primer doseže 254,4 VAC in je še vedno v mejah tolerance, največja nazivna napetost izdelka 220 VAC pa je le 242 VAC. Napajanje 220 VAC lahko pade do 206,8 v okviru tolerance, vendar je najnižja nazivna napetost za pravilno delovanje izdelka 240 VAC 216 VAC. Izdelek 230 VAC mora biti združljiv z vsemi napetostmi v tem območju

Če naj bi se izdelek uporabljal v Združenem kraljestvu, je idealna naprava z napetostjo 240 VAC, vendar se lahko zanesljivo uporabljajo izdelki z napetostjo 240 VAC ali 230 VAC.

Če se izdelek uporablja v celinski Evropi ali Irski republiki, je idealna naprava z nazivom 220 VAC, vendar se lahko brez skrbi uporabljajo izdelki z nazivom 220 VAC ali 230 VAC.

"},{"Title":"Kakšne so razlike med omrežnimi napajanjem 380 V AC, 400 V AC in 415 V AC ter kakšno napetostno opremo naj uporabim?","UrlName":"FAQ000265599","LastModifiedDate":"28/05/2024","score":1.25,"firstpublisheddate":"11/03/2024","answer":"V celinski zahodni Evropi se že vrsto let uporablja trifazno električno omrežje z nazivno napetostjo 380 V AC 50 Hz, v Združenem kraljestvu pa 415 V AC 50 Hz.

Trenutno je vsa zahodnoevropska trifazna oskrba razvrščena v kategorijo 400 V AC. V resnici ni 400-voltnega izmeničnega toka, razen če se ga ustvari na kraju samem. 400 V AC je bil "standard", ki je bil ustvarjen med evropsko "harmonizacijo", da bi zagotovili enoten standard napetosti v zahodni Evropi, vključno z Združenim kraljestvom in Irsko republiko.

Čeprav bi bilo idealno imeti enotno napetost, je bilo preveč političnih, finančnih in tehničnih ovir za zmanjšanje napetosti v Združenem kraljestvu na evropsko raven ali za povečanje evropske napetosti na raven Združenega kraljestva, zato je bil ustvarjen nov standard, ki je zajemal oboje. To je bilo doseženo s spremembo toleranc prej obstoječih standardov oskrbe. Britanska napetost je postala 415 V AC +6 % in -10 %, evropska pa 380 V AC +10 % in -6 % (s čimer se je ustvarilo obvladljivo prekrivanje), ti dve kombinaciji pa smo imenovali 400 V AC, čeprav nihče ni namerno proizvajal 400 V AC!

Glede na napetostno občutljivost izdelka in odstopanje dejanske dobavljene napetosti od nazivne, morda ni priporočljivo uporabljati naprave, ki je specifična za 380 V AC, v Združenem kraljestvu ali 415 V AC v celinski Evropi itd. Na primer, napetost 415 V AC lahko naraste do 439,9 V AC in je še vedno v mejah tolerance, vendar je največja zagotovljena nazivna napetost za izdelek 380 V AC le 418 V AC. Napajanje 380 V AC lahko pade do 357,2 V AC v okviru tolerance, vendar je najmanjša zagotovljena napetost za pravilno delovanje izdelka 415 V AC 373,5 V AC. V vsakem primeru lahko deluje popolnoma pravilno, vendar je lahko tehnično izven specifikacij opreme, kar ima očitne posledice. Izdelek z napetostjo 400 V AC mora biti združljiv z vsemi napetostmi v tem območju.

Če naj bi se izdelek uporabljal v Združenem kraljestvu, je idealna naprava z nazivom 415 V AC, vendar se lahko z gotovostjo uporabljajo izdelki z nazivom 415 V AC ali 400 V AC.

Če se izdelek uporablja v celinski Evropi ali Irski, je idealna naprava z napetostjo 380 V AC, vendar se lahko brez skrbi uporablja izdelke z napetostjo 380 V AC ali 400 V AC."}],"getPv":[],"getPa":[{"Title":"PowerLogic PM5000 serije (PM5100, PM5300, PM5500) Modbus Register seznam","UrlName":"FAQ000265597","LastModifiedDate":"28/05/2024","products":"PM5000 series","score":1.2857142857142856,"firstpublisheddate":"04/03/2024","answer":"
\n
Predmet:
Seznam registrov za Modbus komunikacijo
 
Linija izdelkov
PM5110, PM5330, PM5340, PM5560 in PM5563
 
Okolje
Seznam registrov za Modbus komunikacijo za merilnike električne energije.
 
Vzrok
Za Modbus komunikacijo serije PM5000 je potreben seznam registrov.
 
Ločljivost
Za seznam registrov glej priložene dokumente.

Za navodila za namestitev in uporabo merilnikov ponudbe PM5000 glej dokument "PowerLogic PM5000 Series (PM5100, PM5300, PM5500) Installation and User Guide".

Za tehnični list, brošuro in razčlenitev referenc si glej dokument "PowerLogic PM5000 Series Technical Datasheet, Brochure and Part number breakdown".

https://www.se.com/si/sl/product-range/61281-powerlogic-pm5000-serija#documents
\n
"},{"Title":"Ali se na kompaktnih odklopnikih ComPacT NSX lahko nadomesti - zamenja zaščitno enoto?","UrlName":"FAQ000274993","LastModifiedDate":"10/07/2025","products":"ComPacT NSX (2021)","score":1.1428571428571428,"firstpublisheddate":"10/07/2025","answer":"

Da. Na odklopnikih serije ComPacT NSX zaščitno enoto lahko nadomestimo ali zamenjamo z zaščitno enoto druge vrste z omejitvami skladnosti med tokovnimi razredi NSX 100-250A, NSX 400-630A, omejitvami polov in nominalnih tokov teles odklopnikov.

\n

Pri odklopnikih odklopnih moči R, HB1 in HB2 pa nadomestitev ali zamenjava zaščitne enote ni dovoljena.

\n

Za podrobnosti in reference proizvodov glej katalog tega programa:
ComPacT NSX & NSXm Circuit Breakers and Switch Disconnectors from 16 to 630A up to 690V - May 2024
https://www.se.com/si/sl/download/document/LVPED221001EN/

"},{"Title":"Ali se lahko NSX MCCB napajajo od zgoraj ali od spodaj?","UrlName":"FAQ000274455","LastModifiedDate":"28/05/2025","products":"ComPacT NSX (2021)","score":1.1428571428571428,"firstpublisheddate":"28/05/2025","answer":"

Serijo odklopnikov NSX MCCB je mogoče napajati z zgornje ali spodnje strani.

\n

Uporabljajo se lahko kot vhodne ali izhodne naprave; napajajo se lahko na zgornjih, ali spodnjih močnostnih priključkih, če so opremljeni z zaščitnimi enotami TMD ali Micrologic.

Tudi, če je opremljen z zaščitno enoto Micrologic 4.X z vgrajeno zaščito pred diferenčnim tokom ali z modulom za zaščito pred diferenčnim tokom Vigi brez zmanjšanja zmogljivosti.

Ta lastnost omogoča enostavnejšo povezavo, ko je odklopnik nameščen v razdelilni omari.

\n


Vse priključne in izolacijske dodatke lahko uporabljate na odklopnikih, ki so napajani z zgornje ali spodnje strani.

\n

Skladno s katalogom tega programa:

\n

https://www.se.com/si/sl/download/document/LVPED221001EN/

\n

velja omejitev le za odklopnike odklopne moči R, HB1 in HB2.

"},{"Title":"Minijaturni inštalacijski odklopniki v ponudbi","UrlName":"FAQ000268599","LastModifiedDate":"28/05/2025","products":"Multi 9 C60 UL489 MCB, C60 UL/CSA/IEC, Acti 9 iC60, Acti 9 iK60","score":1.1428571428571428,"firstpublisheddate":"28/05/2025","answer":"

V ponudbi na tržišču Slovenije so minijaturni inštalacijski odklopniki
Acti 9 iC60
https://www.se.com/si/sl/product-range/7556-acti-9-ic60/#products


Acti 9 iK60
https://www.se.com/si/sl/product-range/7557-acti-9-ik60/12367681725-miniaturni-odklopnik/?selected-node-id=12367681755&N=brand%3Dse%26country-code%3DSI%26language-code%3Dsl%26node-id%3D12367681725%26subnode-id%3D12367681755#products

Acti9 iC40
https://www.se.com/uk/en/product-range/65251-acti9-ic40/#products

Multi9
https://www.se.com/si/sl/product-range/1104-multi9/?N=brand%3Dse%26country-code%3DSI%26language-code%3Dsl&selected-node-id=12367768059#products

Odklopnik lahko izbirate ali po lastnostih na levi strani ob listi proizvodov ali po naših PDF katalogih, ki so dostopni na zavihkih 'Dokumenti' preko spletnih katalogov ali preko spletnih strani:
https://www.se.com/si/sl/download/

https://www.se.com/si/sl/download/doc-group-type/20072674-Katalogi+in+bro%C5%A1ure/?sortByField=Popularity

Za enoznačno določitev odklopnika potrebujete vsaj sledeče podatke:
- Število polov
- Nominalni tok
- Odklopno moč (in standard za določeno odklopno moč pri določeni napetosti)
- Tip krivulje odklopa
poleg zgornjih nujnih podatkov so dodatni podatki lahko še ali ima enojne ali dvojne kontakte, ali ima (potrebuje) odklopnik pomožne naprave, kot so pomožni kontaktni bloki za signalizacijo, izklopilne tuljave in katerega tipa naj bo tuljava ter njena krmilna napetost, način vgradnje (nekateri nudijo možnost podnožja).

"},{"Title":"Kako deluje sprožilec, ki mehansko sproži izklop odklopnika?","UrlName":"FAQ000265267","LastModifiedDate":"28/05/2024","products":"Acti 9 iC60, ComPacT NSX (2021), ComPacT NSX NA (2021), EasyPact CVS","score":1.1428571428571428,"firstpublisheddate":"16/02/2024","answer":"Tip izdelkov:
Odklopniki in stikala

Pojasnilo:
Sprožilna naprava je dodatna neobvezna oprema odklopnika. Krmili jo specifična krmilna napetost. Sprožilna naprava mehansko sproži odpiranje odklopnika, ko se izpolni pogoj glede na vrsto sprožilnika ali, pade krmilna napetost pod določeno mejo ali pa se na sprožilnik spusti krmilna napetost.
Napajanje sprožilca se ne vrši preko odklopnika, temveč se le-ta napaja iz zunanjega vira."},{"Title":"Kakšen je pomen oznak 2P2d, 3P3d, 4P3d, 4P4d, 4P3d+N/2 in 4P3d+OSN na kompaktnih odklopnikih NSX?","UrlName":"FAQ000274474","LastModifiedDate":"28/05/2025","products":"ComPacT NSX (2021)","score":0.14285714285714285,"firstpublisheddate":"28/05/2025","answer":"

S pretokovnim sprožilcem se zagotovi zaščito pola. 

\n

Pol, ki nima pretokovnega sprožilca ni zaščiten.

Prva cifra v oznaki ustreza številu polov.
Druga cifra v oznaki ustreza številu zaščitenih polov.
Črka 'P' označuje pol.
Črka 'd'  označuje pole, ki so zaščiteni s sprožilno enoto ("déclencheur" v francoščini).
 
Primeri:
4P3d je 4-polna sprožilna enota s 3 zaščitenimi poli (nevtralni pol ni zaščiten).
4P4d je 4-polna sprožilna enota s 4 zaščitenimi poli (vključno z nevtralnim).
4P3d+N/2 je 4-polna sprožilna enota s 3 zaščitenimi poli in nevtralnim s polovičnim nazivnim tokom, ker ima kabel za nevtralni pol polovični presek v primerjavi s kablom za faze
4P3d+OSN je 4-polna sprožilna enota s 3 zaščitenimi poli in predimenzionirano zaščito nevtralnega vodnika (Over Sized Neutral; za tiste tokokroge, ki so močno onesnaženi s harmoničnimi motnjami).

"}]}" translations="{"tabs":{"popularArticles":"Priljubljeni članki","popularVideos":"Priljubljeni videoposnetki","generalKnowledge":"Splošno znanje","sections":{"popularVideosTitle":"Priljubljena pogosta vprašanja - Videoposnetki","popularVideosTitleMobile":"Priljubljeni videoposnetki","generalKnowledgeTitle":"Preberi več med našimi pogostimi vprašanji splošnega znanja","generalKnowledgeTitleMobile":"Splošno znanje"}},"searchDocument":{"category":"Kategorija izdelka","publishedDate":"Objavljeno dne","modifiedDate":"Nazadnje spremenjeno dne"},"moreButton":{"labelMore":"Pokaži več","labelLess":"Pokaži manj"},"Redirection":{"message":"Pogosta vprašanja, ki jih iščeš, niso več na voljo. Preusmerili smo te na domačo stran za pogosta vprašanja v izbrani državi. Za iskanje po poizvedbi uporabi iskalno vrstico s pogostimi vprašanji, ki je na voljo na domači strani."}}" env="new" s-id="5800">
PowerLogic PM5000 serije (PM5100, PM5300, PM5500) Modbus Register seznam

Predmet: Seznam registrov za Modbus komunikacijo Linija izdelkov PM5110, PM5330, PM5340, PM5560 in PM5563 Okolje Seznam registrov za Modbus komunikacijo za merilnike električne energije. Vzrok Za...

Ali se na kompaktnih odklopnikih ComPacT NSX lahko nadomesti - zamenja...

Da. Na odklopnikih serije ComPacT NSX zaščitno enoto lahko nadomestimo ali zamenjamo z zaščitno enoto druge vrste z omejitvami skladnosti med tokovnimi razredi NSX 100-250A, NSX 400-630A, omejitvami...

Ali se lahko NSX MCCB napajajo od zgoraj ali od spodaj?

Serijo odklopnikov NSX MCCB je mogoče napajati z zgornje ali spodnje strani. Uporabljajo se lahko kot vhodne ali izhodne naprave; napajajo se lahko na zgornjih, ali spodnjih močnostnih priključkih,...

Minijaturni inštalacijski odklopniki v ponudbi

V ponudbi na tržišču Slovenije so minijaturni inštalacijski odklopniki Acti 9 iC60 https://www.se.com/si/sl/product-range/7556-acti-9-ic60/#products Acti 9 iK60...

Kako deluje sprožilec, ki mehansko sproži izklop odklopnika?

Tip izdelkov: Odklopniki in stikala Pojasnilo: Sprožilna naprava je dodatna neobvezna oprema odklopnika. Krmili jo specifična krmilna napetost. Sprožilna naprava mehansko sproži odpiranje odklopnika,...

Kakšen je pomen oznak 2P2d, 3P3d, 4P3d, 4P4d, 4P3d+N/2 in 4P3d+OSN na...

S pretokovnim sprožilcem se zagotovi zaščito pola. Pol, ki nima pretokovnega sprožilca ni zaščiten. Prva cifra v oznaki ustreza številu polov. Druga cifra v oznaki ustreza številu zaščitenih polov....

Pokaži več
Preberi več med našimi pogostimi vprašanji splošnega znanjaSplošno znanje
Kakšna je razlika med PNP in NPN pri opisu 3-žične povezave senzorja?

Večina industrijskih senzorjev (induktivni, kapacitivni, ultrazvočni in fotoelektrični senzorji) je polprevodniških. Izraz polprevodniški se nanaša na vrsto komponent, uporabljenih v senzorju....

Kakšne so razlike med omrežnimi napajalniki 220 VAC, 230 VAC in 240 VAC...

V celinski zahodni Evropi se že vrsto let uporablja električno omrežje z nazivno napetostjo 220 VAC 50 Hz. V Združenem kraljestvu se uporablja 240 VAC 50 Hz. Trenutno so VSE zahodnoevropske mreže...

Kakšne so razlike med omrežnimi napajanjem 380 V AC, 400 V AC in 415 V AC...

V celinski zahodni Evropi se že vrsto let uporablja trifazno električno omrežje z nazivno napetostjo 380 V AC 50 Hz, v Združenem kraljestvu pa 415 V AC 50 Hz. Trenutno je vsa zahodnoevropska trifazna...

  • A man Searching something in laptop

    Support Center

  • Download Center

Potrebuješ pomoč?

Potrebuješ pomoč?

Orodje za izbor izdelkov

Orodje za izbor izdelkov

Hitro in preprosto poišči prave izdelke ter dodatno opremo za svoje načine uporabe.

Pridobi ponudbo

Pridobi ponudbo

Začni poizvedbo prek spleta, strokovnjak pa bo vzpostavil stik s tabo.

Kje kupiti izdelke?

Kje kupiti izdelke?

Enostavno poišči svojega najbližjega distributerja Schneider Electric.

Center za pomoč

Center za pomoč

Poišči vire za podporo za vse svoje potrebe na enem mestu.

  • Dokumentacija izdelkov
  • Prenosi programske opreme
  • Konfigurator izdelkov
  • Nadomestitev in zamenjava izdelka
  • Center za pomoč in stike
  • Poišči naše pisarne
  • Kje kupiti
  • Splošni pogoji poslovanja
  • Skupnost podjetja Schneider Electric
  • Kariera
  • Profil podjetja
  • Prijavi kršitev
  • Dostopnost
  • Vlagatelji
  • EcoStruxure
  • Iskanje delovnih mest
  • Blog
  • Pravilnik o zasebnosti
  • Obvestilo o piškotkih
  • Pogoji uporabe
  • Change your cookie settings