Goals and Symptoms

Here are the minimum characteristics that a barcode reader needs to have in order to be supported by Vijeo-Designer when connected to an XBTG (for serial barcode readers) or XBTGT (for serial or USB barcode readers) target:

Facts and Changes

Vijéo-Designer

Causes and Fixes

1. The barcode reader needs to send data as ASCII strings.
2. A serial barcode reader needs to be able to change its communication settings for the following parameters:
- baud rate.
- data length.
- parity bit setting.
- stop bit setting.
- end mark: the end marks supported are CR (Carriage Return) and CR+LF (Carriage Return followed by Line Feed).
3. A USB barcode reader needs:
- to belong to the class of USB devices called HID (Human Interface Device). For information, this is the USB device class that keyboards and mice belong to.
- to be able to change its end mark. The end marks supported are CR (Carriage Return) and CR+LF (Carriage Return followed by Line Feed).

Concerning the ability for a barcode reader to change its communcation settings, it is most often done by scanning a particular barcode on a page of the user manual of the barcode reader. Therefore, for the manufacturers that publish the user manuals of their PRODUCTS (most often as PDF files) on their corporate Web sites, checking for this possibility in the user manual online before purchasing the barcode reader is a good idea....

施耐德電機Taiwan

探索更多
系列:
探索更多
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings