Web Reporter: Error Setting Web Service Identity

Goals and Symptoms

This KB applies to ION Enterprise 6.0 and up on Windows Server 2008 (x64) with SQL 2005 (x64).
Running the RSConfigurationWizard tool will throw an error:

Error Setting Web Service Identity

At this point, the setup will not complete and will quit.

Causes and Fixes

1. Browse to the Microsoft SQL Server Reporting Services Instance folder:
C:\Program Files\Microsoft SQL Server\MSSQL.2\Reporting Services\ReportServer
(this path may very depending on your installation)

2. Manually edit rsreportserver.config:
Right Click on the file and Open With notepad.exe

3. Use Ctrl + F to find the WebServiceAccount tag.

4. Check if the Web Service Account tag is empty:
<WebServiceAccount></WebServiceAccount>

5. If the tag is empty add NT Authority\NetworkService and save so it looks like:
<WebServiceAccount>NT Authority\NetworkService</WebServiceAccount>

6. Restart Reporting Services service

7. Open up IIS configuration

8. Browse to the Application Pools

9. Open up the Advanced Options for the Classic .NET AppPool

10. Set Identity to NetworkService (see screen shot)

11. Repeat for DefaultAppPool



12. Run RS2008WRConfiguration Wizard (see RESL203767)


Legacy KB System (APS) Data: RESL205150 V1.0, Originally authored by DaDu on 04/22/2011, Last Edited by DaDu on 04/22/2011
Related ranges: ION Enterprise V6.0

施耐德電機Taiwan

探索更多
系列:
探索更多
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings