How to stop the Product Registration pop-up dialog when opening the Management Console in PME?

Issue
When opening the Management Console and authenticating (as a user with level 3 access or higher) a registration reminder dialog will appear asking to register the product. The normal workflow involves a user registering the product through one of the provided mechanisms. Once a product is registered the registration reminder pop-ups will no longer appear.

Here is the registration dialog:

"This product is not registered!
In order to improve our service, we ask you to register your version of StruxureWare Power Monitoring Expert.
Do you want to register now?"

Product not registered

Product Line
StruxureWare Power Monitoring 7.0.x
Power Monitoring Expert 7.2.x
Power Monitoring Expert 8.x
Power Monitoring Expert 9.0
Power Monitoring Expert 2020
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023

Environment
Software Registration

Cause
Registration is not fully complete and the register is not changed automatically

Resolution

*Warning: This article contains information about editing the registry. Improper changes to the registry can permanently damage the operating system. Always backup the registry before making any changes.*

Note: Disabling registration is not recommended unless It prevents use of the Management Console The preferred course of action is to complete the registration process!

How to disable Registration manually:

Add a new Registry String Value in the following location with a Value name "Disabled" and Value data "1" without the quotation marks:

32-bit systems:

  • Registry Key Path:
    • HKEY_LOCAL_MACHINE\SOFTWARE\Schneider Electric\ StruxureWarePowerMonitoring\7.0\License
    · Add new Registry String Value:
    • Disabled = 1
64-bit system:
  • Registry Key Path:
    • HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Schneider Electric\ StruxureWarePowerMonitoring\7.0\License
    · Add new Registry String Value:
    • Disabled = 1

This will stop Product Registration and the registration reminder pop-ups.

施耐德電機Taiwan

探索更多
系列:
探索更多
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings