Can Webreach access a mapped drive?
Issue
Can Webreach access information on a mapped drive?
Product
Power Monitoring Expert
Enviorment
Web Application
Resolution

No, it is not possible


Explanation:
To display the network diagram, Webreach needs to pull out some information from the ud folder, located on the IIS server.

Here is an example of when you try to access a diagram on a mapped drive.


web error

Error reads:

  • The diagram does not exist, or you do not have permission to access it

The address bar contains the mapped drive location "Y:" which causes the problem.

The fact that the user cannot use mapped drives with Webreach is actually a limitation of the IIS. Here is Microsoft's explanation:
"When you create or administer a Web site or virtual directory, the option to browse for the physical location where the content is stored for that site or virtual directory includes mapped drives. This may be interpreted as a way to keep the content on a network share accessible through the mapped drive; however, because the nature of drive mappings, this is not a viable option. If you prefer to keep your content on a remote computer, then create the Web site or virtual directory with a universal naming convention (UNC) path to point to the share on the remote computer."
Generally, the problem is that the mapped drives are set on a per-user basis.  The user who has mapped the drive is not the same user (IUSR_<machine>) who is trying to access that drive from Webreach.

施耐德電機Taiwan

探索更多
產品:
探索更多
產品:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings