我們的品牌

歡迎造訪施耐德電機全球網站

歡迎訪問我們的網站
		
我们今天能为您提供什么帮助?
SQL Server Disk Space Monitor Alerts
Issue
Need to automate the process to monitor the total disk space and available disk space and send an alert at a
predetermined threshold in order to prevent running out of space and the problems that would be associated.

Product Line
ION Enterprise 6.0.x
StruxureWare Power Monitoring 7.0.x
Power Monitoring Expert 7.x
Power Monitoring Expert 8.x
Power Monitoring Expert 9.x
Power Monitoring Expert 2020
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023
ION EEM

Environment
SQL Server 2005, SQL Server 2008 R2, SQL Server 2012, SQL Server 2014, SQL Server 2016, SQL Server 2017, SQL Server 2019

Cause
Proactive automated system maintenance best practice.

Resolution
*Warning: Irreparable database damage can occur. This procedure should only be performed by users familiar with SQL Server Management Studio. Databases should be backed up prior to performing this procedure.*

The following stored procedure sends an alert when any drive size drops below a set threshold and also
includes an attachment of all the folders and files inside each folder and its size in Bytes in the drive where
we have the space deficiency. Also in the mail, it provides the information about which drive is running low on space.

To implement this:
1) highlight and copy the script below or download the attached file to a desired location
2) launch SQL Server Management Studio either:
- open a new Query window and paste the text copied from below
- select File -> Open,  then locate the downloaded file to open
3) execute the script within the Query window to create the stored procedure
4) create a new scheduled SQL job to execute the stored procedure with your parameters as per the Example contained in the script.
** Further information on how to create and schedule a SQL job can be found within your SQL Server documentation or obtained using the Help within SSMS.

SET ANSI_NULLS ON
GO
SET QUOTED_IDENTIFIER ON
GO
/*----------------------------------------------------------------------------------------------------------
Desc: Send Disk space alert with free space details in each drive
------------------------------------------------------------------------------------------------------------
input: @mailto - recipients list
@mailProfile - DBMail Profile.
@threshold - Threshold Free space in MB below which you need the alert to be sent.
@logfile - Log file to hold the file size details and send it as an attachment.
output: Send Mail
Warnings: None.
------------------------------------------------------------------------------------------------------------
Example: EXEC [DiskSpaceMntr]
@mailProfile = 'SQL_Profile',
@mailto = 'mymailid@mymail.com',
@threshold = 10240,
@logfile = 'D:\DBA\DiskSpaceLog.txt'
------------------------------------------------------------------------------------------------------------*/
/****** Object: Stored Procedure dbo.DiskSpaceMntr******/
CREATE PROCEDURE [dbo].[DiskSpaceMntr]
@mailProfile nvarchar(500),
@mailto nvarchar(4000),
@threshold INT,
@logfile nvarchar(4000)
AS
BEGIN
declare @count int;
declare @tempfspace int;
declare @tempdrive char(1);
declare @mailbody nvarchar(4000);
declare @altflag bit;
declare @sub nvarchar(4000);
declare @cmd nvarchar(4000);
SET @count = 0;
SET @mailbody = '';
SET @cmd = '';
SET NOCOUNT ON
--Create temp table to hold drive-free space info
IF EXISTS(select * from sys.sysobjects where id = object_id('#driveinfo'))
drop table #driveinfo
create table #driveinfo(id int identity(1,1),drive char(1), fspace int)
insert into #driveinfo EXEC master..xp_fixeddrives
--Loop through each drive to check for drive threshold
while (select count(*) from #driveinfo) >= @count
begin
set @tempfspace = (select fspace from #driveinfo where id = @count)
set @tempdrive = (select drive from #driveinfo where id = @count)
--If free space is lower than threshold appends details to mail body and dumps the file size details into the logfile.
if @tempfspace < @threshold
BEGIN
SET @altflag = 1;
SET @mailbody = @mailbody + '
Drive ' + CAST(@tempdrive AS NVARCHAR(10)) + ' has ' + CAST(@tempfspace AS NVARCHAR(10)) + ' MB free
'
SET @cmd = 'dir /s /-c ' + @tempdrive + ':\ > ' + @logfile
EXEC xp_cmdshell @cmd
END
set @count = @count + 1
end
--If at least one drive is below threshold level sends the mail with attachment
IF (@altflag = 1)
BEGIN
SET @sub = 'Monitor Space on ' + CAST(@@SERVERNAME AS NVARCHAR(30))
EXEC msdb.dbo.sp_send_dbmail
@profile_name = @mailProfile,
@recipients= @mailto,
@subject = @sub,
@body = @mailbody,
@file_attachments = @logfile,
@body_format = 'HTML'
END
drop table #driveinfo
set nocount off
END

施耐德電機Taiwan

附件
DiskSpaceAlert.sql [2.87 KB]
探索更多
產品:
探索更多
產品:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings