我們的品牌

歡迎造訪施耐德電機全球網站

歡迎訪問我們的網站
		
我们今天能为您提供什么帮助?
DCOM Error 10016 on SQL Agent Job Execution

Issue
Each time a SQL job tries to execute, the following error occurs in the Windows System Event log:

Log Name: System
Source: Microsoft-Windows-DistributedCOM
Date: 02.02.2013 16:00:02
Event ID: 10016
Task Category: None
Level: Error
Keywords: Classic
User: SQL AGENT Service account
Computer: SQL Server
Description:
The application-specific permission settings do not grant Local Launch permission for the COM Server application with CLSID
{46063B1E-BE4A-4014-8755-5B377CD462FC}
and APPID
{FAAFC69C-F4ED-4CCA-8849-7B882279EDBE}
to the user "SQL AGENT Service account "SID (S-1-5-21-) from address LocalHost (Using LRPC). This security permission can be
modified using the Component Services administrative tool.


Product Line

ION Enterprise 6.0x

Power Monitoring Expert 7.0.1

Power Monitoring Expert 7.2.x

Power Monitoring Expert 8.x
Power Monitoring Expert 9.0


Environment
Power Monitoring Expert Server
Windows Component Services

Cause
The SQL Server Agent service lacks the Local Activation permission for the MsDtsServer100 DCOM application. This typically happens when the SQL Server Agent service is configured using a domain user account, or is not a
member of the Administrators group.

Resolution
*Warning: This article contains information about editing the registry. Improper changes to the registry can permanently damage the operating system. Always backup the registry before making any changes.*

One solution would be to add the SQL Server Agent service account to the Local Administrators group on the server; however, this is not always allowed per the user's specific security requirements. To add an account to the Local Administrators group:

  1. From the Windows start menu, type lusrmgr.msc and hit Enter to open the Edit Local Users and Groups interface.
  2. Select Groups on the left, then right-click on the Administrators group and select Properties.
  3. Click Add and then type the name of the user running the SQL Server Agent service, click Check Names, and hit OK.

Another solution would be modifying the Local Activation permission for the MsDtsServer100 DCOM application. To do this, follow the steps below.

  1. Open the Registry Editor by typing regedit in the windows start menu. Right click and select run As Administrator.
  2. Highlight Computer at the top of the list on the left of the screen.
  3. Open the Edit tab at the top and select Find.
  4. Paste the CLSID that was referenced in the error from the Windows System Event log.
  5. Expand the key titled as the CLSID, and highlight LocalService to confirm that the DCOM application in question is MsDtsServer100 (see image below).Registry editor Local Service
  6. Check and/or modify the permissions assigned to the DCOM application (MsDtsServer100) by going to the windows start menu and typing DCOMCNFG, hit Enter.
  7. Expand Component Services > Computers > My Computer > DCOM Config
  8. Scroll down to the MsDtsServer100 application, and right-click the application to open its properties
  9. Go to the Security tab, and click the Edit button under "Launch and activation permissions"
  10. Edit the explicit local launch permissions by adding/modifying the account configured to run the SQL Server Agent service (see image below).
Launch and Activation Permission

施耐德電機Taiwan

探索更多
系列:
探索更多
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings