What IIS Components are required for PME installation?

Issue:

The customer wants to know which IIS components must be installed before performing PME installation and how to verify that all components were installed correctly. Missing components can cause PME Web Applications (Dashboards, Diagrams, Reports) to fail.

Product Line:

Power Monitoring Expert 7.2

Power Monitoring Expert 8.x

Power Monitoring Expert 9.x

Power Monitoring Expert 2020

Power Monitoring Expert 2021

Power Monitoring Expert 2022

Power Monitoring Expert 2023

Power Monitoring Expert 2024

Environment:

Windows Server with IIS

PME Web Applications

Cause:

Uninstalling or missing IIS components will cause some segments of PME Web Applications not to function properly.

Resolution:

Install IIS and the following role services before starting PME installation:

Required IIS Role Services

i) Common HTTP Features

  • Static Content
  • Default Document
  • Directory Browsing
  • HTTP Errors

ii) Health and Diagnostics

  • HTTP Logging
  • Request Monitor

iii) Security

  • Request Filtering

iv) Performance Features

  • Static Content Compression

v) Management Tools

  • IIS Management Console

Application Development Features

  • ASP.NET
  • .NET Extensibility (aligned with OS version, e.g., .NET 4.8 for Windows Server 2019/2022)
  • ASP
  • ISAPI Extensions
  • ISAPI Filters

Tip: If prompted, click Add Required Role Services to include dependencies.

Management Tools

  • IIS 6 Management Compatibility
    • IIS 6 Metabase and IIS configuration compatibility
    • IIS 6 WMI Compatibility
    • IIS 6 Scripting Tools

Conditional Components

  • Windows Authentication
    Required only if PME is installed with Windows Integrated Authentication.

Best Practice

  • Add roles via Server Manager → Add Roles and Features.
  • Click Add Required Role Services when prompted.
  • Restart IIS after installation:

Recommendation:

If you are using an older version of PME, consider upgrading to the latest version for improved protocol support and security. For assistance with integration or upgrades, contact Schneider Electric Technical Support at: pmo-psup@se.com

Support Details

施耐德電機Taiwan

探索更多
系列:
探索更多
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings