我们今天能为您提供什么帮助?

Video: How do I assign an IP address to a Lexium Integrated Drive that supports Ethernet IP?

A demonstration video was created which shows how to assign an IP address using the built-in web page that is available on Lexium Integrated Drives.
The video covers ILS2K , ILE2K and ILA2K devices.

If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.

If you are not located in North America, please contact your local Customer Care Center for assistance:

Support | Schneider Electric Global (se.com)

施耐德電機Taiwan

探索更多

探索更多

需要協助?

產品選型工具

快速輕鬆地為您的應用找到合適的產品和附件。

取得報價

立即線上提交您的銷售需求,專業團隊將主動聯繫您。

購買地點

輕鬆在您所在地區找到最近的施耐德電機經銷商。

支援中心

在同一位置找到滿足您所有需求的支援資源。