我們的品牌

歡迎造訪施耐德電機全球網站

歡迎訪問我們的網站
		
我们今天能为您提供什么帮助?
Geo SCADA: Licensing a ViewX client with a license file

Problem

This article explains how to match up and install a ViewX license file in the associated ViewX client PC.

Solution

1) Open the license file using Windows Notepad.  You should see something like the screen shot below (note the 'MachineID' string)

image1

2) On the ViewX client PC click on the Windows Start button and navigate to EcoStruxure Geo SCADA | Configure Connections.  The Geo SCADA Client dialog should open as shown below.


image2

3) Click the 'Licenses' button (circled in red above).  The 'Client Licensing' dialog should appear as shown below.  Look at the Machine ID field.


image3

4) The machine ID in this dialog should match the machine ID shown in the license file.  If they do not match, you will need to check if another license file is available until you find the one that matches.  Once you find the matching license file click on the box with the 3 dots next to the license file field (as shown below)


image4

5) Navigate to the location of the license file and then click the 'Open' button

Note: it is recommended that users save the license file to folder C:\Program Files\Schneider Electric\ClearSCADA.  If the license file is saved in too deep a path (in the Windows directory), the Geo SCADA License Server may not recognize the license file.

image5

6) If the license installation was successful the 'License Mode' field should read "File based client license" and the 'Validity' field should read "Valid"
(Note: you may need to hit either the 'Apply' or 'Refresh' button first)


image6

7) Repeat these steps above for any other ViewX clients until all have been successfully licensed.

施耐德電機Taiwan

探索更多
系列:
探索更多
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings