Unity returns error when opening PRA application from older version of Unity.
Issue
Unity returns error when opening PRA application from older version of Unity.

Product Line
Unity

Environment
Windows 10

Resolution
If you try to open the PRA application by clicking on 'Launch PRA' (See Figure 1)from a Unity application that has been converted from an older version of Unity,  you could get the following error (See Figure 2):

Figure 1.
ggtg


Figure 2.
rgtwtw


The reason the error occurred is because the application was not migrated in accordance to the instructions defined in the online help for Unity which is also shown below:
  • SD Card Application Restriction
An application on a SD Card designed for the BMX PRA 0100 can only be executed on a BMX PRA 0100. It cannot be executed on the BMX P34 CPUs.
  • Import/Export mechanism
The master *.STA file generated in Unity Pro v6.0 cannot be fully opened in Unity Pro v7.0 and upper. Slave projects are saved in *.STU format that are not compatible when updating Unity Pro from one version to another.
Here below is described the way to fully retrieve the master *.sta and the *.stu slave applications:
In Unity Pro v6.0
    • *.ZEF file (Full Application Exchange Files) to import a global project with global DTMs configuration
    • *.XEF file (Application Exchange Files) to import a global project without global DTMs configuration
  • Export slave BMX PRA 0100 project
    For All BMX PRA 0100 restore the slave project:
    • launch the I/O Scanning
    • select a slave BMX PRA 0100
      A new Unity Pro window opens
    • File → Export
    • The global project *.ZEF or *.XEF files
In Unity Pro v7.0 and upper
    • File → Open
    • The global project *.ZEF or *.XEF files saved in Unity Pro v6.0 to be selected
  • Restore Unity Pro slave project files
    For All BMX PRA 0100 restore the slave project:
    • launch the I/O Scanning
    • select a slave BMX PRA 0100
      A new Unity Pro window opens
    • File → Open
    • The global project *.ZEF or *.XEF files saved in Unity Pro v6.0 have to be selected
NOTE: This migration can also be achieved using Save Archive.
In Unity Pro v6.0
In Unity Pro v7.0 and upper
    • File → Open
    • The archive *.STA file saved in Unity Pro v6.0 have to be selected
  • Open slave Archive
    • launch the I/O Scanning
    • select a slave BMX PRA 0100
      A new Unity Pro window opens
    • File → Open
    • The archive *.STA file saved in Unity Pro v6.0 have to be selected

施耐德電機Taiwan

探索更多
系列:
探索更多
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings