Power manager Integration Utility - When this utility is run, the error message "Export complete with errors. Please check logs for details" is seen
Cause
Running the Power Manager Integration utility with Windows user account instead of Administrator account

Log:
2016-10-12 15:09:33 - ERROR: System.Security.SecurityException: Requested
registry access is not allowed.
at System.ThrowHelper.ThrowSecurityException(ExceptionResource resource)
at Microsoft.Win32.RegistryKey.OpenSubKey(String name, Boolean writable)
at
IntegrationUtility.Services.ProductRegistry.GetProductRegistryValue(String
subkey, String valueName)
The Zone of the assembly that failed was:
MyComputer
2016-10-12 15:10:19 - ERROR: Error enabling EWS: Exception is:
System.InvalidOperationException: Failed to map the path '/ews'.
at System.Web.Configuration.ProcessHostConfigUtils.MapPathActual(String
siteName, VirtualPath path)
at System.Web.Configuration.ProcessHostMapPath.MapPathCaching(String
siteID, VirtualPath path)
at
System.Web.Configuration.ProcessHostMapPath.System.Web.Configuration.IConfigMapPath2.MapPath(String
siteID, VirtualPath path)
at
System.Web.Configuration.WebConfigurationHost.InitForConfiguration(String&
locationSubPath, String& configPath, String& locationConfigPath,
IInternalConfigRoot configRoot, Object[] hostInitConfigurationParams)
at System.Configuration.Configuration..ctor(String locationSubPath, Type
typeConfigHost, Object[] hostInitConfigurationParams)
at
System.Configuration.Internal.InternalConfigConfigurationFactory.System.Configuration.Internal.IInternalConfigConfigurationFactory.Create(Type
typeConfigHost, Object[] hostInitConfigurationParams)
at
System.Web.Configuration.WebConfigurationHost.OpenConfiguration(WebLevel
webLevel, ConfigurationFileMap fileMap, VirtualPath path, String site,
String locationSubPath, String server, String userName, String password,
IntPtr tokenHandle)
at
IntegrationUtility.Services.ConfigurationProcessor.SetWebConfigurationValue(String
virtualPath, String key, String value)
at IntegrationUtility.Services.ConfigurationProcessor.EnableEws().
2016-10-12 15:10:19 - ERROR: Error enabling token service: Exception is:
System.InvalidOperationException: Failed to map the path
'/systemdataservice'.
at System.Web.Configuration.ProcessHostConfigUtils.MapPathActual(String
siteName, VirtualPath path)
at System.Web.Configuration.ProcessHostMapPath.MapPathCaching(String
siteID, VirtualPath path)
at
System.Web.Configuration.ProcessHostMapPath.System.Web.Configuration.IConfigMapPath2.MapPath(String
siteID, VirtualPath path)
at
System.Web.Configuration.WebConfigurationHost.InitForConfiguration(String&
locationSubPath, String& configPath, String& locationConfigPath,
IInternalConfigRoot configRoot, Object[] hostInitConfigurationParams)
at System.Configuration.Configuration..ctor(String locationSubPath, Type
typeConfigHost, Object[] hostInitConfigurationParams)
at
System.Configuration.Internal.InternalConfigConfigurationFactory.System.Configuration.Internal.IInternalConfigConfigurationFactory.Create(Type
typeConfigHost, Object[] hostInitConfigurationParams)
at
System.Web.Configuration.WebConfigurationHost.OpenConfiguration(WebLevel
webLevel, ConfigurationFileMap fileMap, VirtualPath path, String site,
String locationSubPath, String server, String userName, String password,
IntPtr tokenHandle)
at
IntegrationUtility.Services.ConfigurationProcessor.SetWebConfigurationValue(String
virtualPath, String key, String value)
at
IntegrationUtility.Services.ConfigurationProcessor.EnableTokenService().

Resolution:
Run the tool with Administrator permissions.

施耐德電機Taiwan

探索更多
系列:
探索更多
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings