Accutech FL10 Float Level Issues and Troubleshooting

The Accutech FL10 wireless float level field unit interfaces with particular digital level sensors for monitoring oil and/or water levels in a tank.

The FL10 supports the following digital level sensors:

·Siemens Model 1000 Digital Level Sensor

·Siemens/Electrolab Model 2100 Digital Level Sensor

·Electrolab RU Flex 2100 Digital Level Sensor


The digital level sensor consists of a probe (or 'stick') with a number of sensors to detect the location of one or two floats that slide freely along the stick. These floats then indicate the tank level of the fluid(s) within the tank.

The FL10 field unit has a number of status codes describing conditions present in the device. The status codes are displayed on the local display of the field unit, reported to the base radio, and displayed in Accutech Manager.  If you are NOT actively monitoring these status codes, you will be able to identify these conditions by monitoring the process values. Instead of seeing a normal reading, a value of 999999.9 will be reported.

Sensor Alert (SENALRT) indicates the sensor could not be measured and is not valid. Older field units may display S FAULT.

  • No Float detected or only one float detected in a two float configuration (floats might be too high or too low on the level stick; the number of floats configured is incorrect; floats have dropped off the bottom of the stick).
  • Misalignment of the floats. Align the white stripe on the float with the white stripe on the tube. If monitoring 2 levels, install the float labeled water towards the bottom of the sensor. If a float is misaligned by 90 degrees, the stick may still be able to see the float intermittently. This could cause the SENALRT to toggle on and off as the float appears and disappears from sight.
  • Invalid response from configuration command.


Level Alert (LVLALRT) indicates that the field unit level measurement may not be valid.

  • The level reading is a negative value. This can occur when a negative offset is used and the float is near the bottom of the stick.
  • The floats are touching and the position of each cannot be precisely determined. This is more common when a 1/2" resolution digital level sensor is used.


System Alert (SYSALRT) indicates that the field unit cannot measure the sensor or can not communicate with the sensor.

  • The Siemens FL10 did not respond to a configuration or measurement command. This could be from a loose connection between the head and the stick.
  • The Siemens FL10 responded with an invalid message or check sum.

施耐德電機Taiwan

探索更多
系列:
探索更多
系列:

需要協助?

  • 產品選型工具

    快速輕鬆地為您的應用找到合適的產品和附件。

  • 取得報價

    立即線上提交您的銷售需求,專業團隊將主動聯繫您。

  • 購買地點

    輕鬆在您所在地區找到最近的施耐德電機經銷商。

  • 支援中心

    在同一位置找到滿足您所有需求的支援資源。

  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings