Do M221 controllers have retentive timers?

Issue:
Are there retentive timers for the M221?

Product Line:
TM221

Environment:
EcoStruxure Machine Expert Basic (formally SoMachine Basic)

Cause:
Programming questions on how to create a retentive timer.

Resolution:
M221 controllers have retentive timers. The checkbox for Retentive will have to be checked under the Programming tab / Tools tab / Software Objects / Timers or by clicking on the specific Timer in the program and then on the Retentive check-box.