How to update the HMIG3U Vijeo Designer Runtime to EcoStruxure Operator Terminal Expert?

Article available in these languages: 西班牙文

Issue:
If I have a previously purchased HMIG3U running Vijeo Designer Runtime and I wish to migrate it to EcoStruxure Operator Terminal Expert, what are the steps?

Product Line:
HMIG3U, EcoStruxure Operator Terminal Expert (Vijeo XD), Vijeo Designer

Resolution:
To update the HMIG3U runtime from Vijeo Designer to EcoStruxure Operator Terminal Expert simply by initiating a downloading to the target from EcoStruxure Operator Terminal configuration software running on your PC over USB cable or Ethernet connection. The conversion cannot be done using a USB memory stick or SD card.
Note: The initial download to update the runtime will take 15-20 minutes to complete.