我们今天能为您提供什么帮助?
ION9000 default webpages for data viewing and meter configuration
Product Line
ION9000 Meter
Environment
Webpages
Resolution
- You can access the meter’s webpages through the meter’s Ethernet connection using a web browser
- You must have cookies enabled in order to access your meter’s webpages
- You may need to configure your meter’s security settings in order to view webpages and configure your meter using webpages
- On a hardware-locked meter, you cannot add, delete or modify any webpage files
- If you are connected to your device over Ethernet, changing Ethernet configuration parameters without another method of configuration enabled may cause loss of communications with your device and render it inaccessible
- The ION9000 meter comes with the default webpages that include:
Monitoring
| Webpage Menu | Webpage Content |
|---|---|
| Instantaneous Readings |
|
| Trending & Forecasting | Select the target and interval for trending and forecasting and view the results. |
| Power Quality Summary |
|
| Inputs/Outputs |
|
| Waveforms | View waveforms from your meter, using the meter’s COMTRADE files |
Control
| Webpage Menu | Webpage Contents |
|---|---|
| Resets | Perform resets, and view when previous resets were performed |
Diagnostics
| Webpage Menu | Webpage Contents |
|---|---|
| Statistics |
|
| Phasor diagram | View the phasor diagram and numeric values |
Setup
| Webpage Menu | Webpage Content |
|---|---|
| Ethernet |
|
| Serial Port |
|
| SNMP Parameters | Configure your meter’s SNMP parameters. |
| NTP | Configure your meter’s NTP parameters |
| SMTP | Configure your meter’s SMTP parameters |
| Date & Time | Configure your meter’s time and time synchronization |
| Preferences | Enter your meter’s nameplate information |
| Metering |
|
| HTTPS | Certificate Management |
Maintenance
| Webpage Menu | Webpage Content |
|---|---|
| — | Custom. No default content. By default, the Maintenance menu is empty, and the menu is not displayed until information is added to it. |
.
ION9000 default webpages file is located here FA363418.
發佈於: 施耐德電機Taiwan