Unity running on 'Windows Server 2016' randomly crashes'

Issue
Unity running on 'Windows Server 2016' randomly crashes'

Product Line
Unity 13.1

Environment
Windows Server 2016


Resolution
Unity running on a PC that has the 'Windows Server 2016 Standard version' operating system will randomly crash.  Examination of the event log file found in the
'Windows Event Viewer\application Log'  will show the following message:
  • Faulting application path:C:\Program Files (x86)\Schneider Electric\Unity Pro
  • Faulting module path:C:\Windows\System32\mfc110u.dll

The Event Viewer log message indicates that there was a problem accessing or running the Microsoft component named 'mfc110u.dll'.  As a result of this, Unity
faulted. The 'mfc110u.dll' is component of the 'mfc110.dll' libraries that get installed by 'Microsoft Studio Visual C++ Redistributable for Visual Studio 2012'.

This issue could be caused by either a bad Windows registry setting or a bad  'mfc110u.dll' file.

To resolve the issue, the user could try reinstalling the ​'Microsoft Studio Visual C++ Redistributable for Visual Studio 2012'.

If the issue still occurs, the following solution can also be performed.
  • Uninstall Unity using the  'Remove Unity Pro XL' option found in the Windows start menu
  • Reboot the PC.
  • Run a registry cleaner (i.e., CCleaner, etc.)
  • Reboot the PC.
  • Install Unity.
  • Retest.

施耐德電機Taiwan

探索更多
系列:
探索更多
系列:

需要協助?

需要協助?

產品選型工具

產品選型工具

快速輕鬆地為您的應用找到合適的產品和附件。

取得報價

取得報價

立即線上提交您的銷售需求,專業團隊將主動聯繫您。

購買地點

購買地點

輕鬆在您所在地區找到最近的施耐德電機經銷商。

支援中心

支援中心

在同一位置找到滿足您所有需求的支援資源。

  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings