我們的品牌

歡迎造訪施耐德電機全球網站

歡迎訪問我們的網站
		
我们今天能为您提供什么帮助?
Why an Exclamation mark as unknown device is shown on Windows device manager of Harmony P6?
The Exclamation mark as unknown device is shown on Windows device manager of Harmony P6.

Capture.JPG

This issue is shown with such hardware:
Harmony P6 SeriesHMIP6******
This Hardware runs a Windows 10 OS image.


To fix this issue and to unshown the Exclamation mark as unknown device on Device Manager,
It can be solved by “Restore Defaults” on BIOS.
  1. Enter the BIOS
1) Turn on the product.
2) While the boot screen is displayed, press either the [DEL] or [ESC] key.
3) Enter the password
(Default password: Please refer "UEFI BIOS" on "Harmony P6, User Manual")

4) The BIOS screen will display.
  1. “Save and Exit” on BIOS
  1. Select” Restore Defaults” and “Enter” by Keyboard

  1. Select “Yes” and “Enter” by Keyboard
211223134333

  1. Select “Save Changes and Reset” by keyboard
211223134328
  1. Select “Yes” and “Enter” by Keyboard

211223134339
  1. Product will be restarted as updated BIOS to unshown the Exclamation mark as unknown device on Device Manager:


施耐德電機Taiwan

探索更多
系列:
探索更多
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings