What is the decommissioning process for the Schneider Electric ConneXium Industrial Firewall?

Use the Secure disposal checklist when disposing a ConneXium Industrial Firewall (TCSEFEA23F3F22) to help prevent potential disclosure of data.

Secure disposal checklist
TaskDescriptionCompleted
Record activitiesDocument disposal actions according to your company’s policies and standards to keep a record of activities.

□

Factory Reset the deviceTo reset the Tofino SA back to its default state as shipped from the factory with configuration and logs erased, you can perform a 'Factory Reset'

Confirm that power is applied to the Tofino SA and it has completed its start-up initialization.

□

Press, then release the "Save Load Reset" button three times so that the three LEDs are illuminated. On the first press, the " 1/s" indicator will be illuminated; on the second press, the " 2/L" indicator will be illuminated; and on the third press, the "V.24/R" indicator will be illuminated.

□

After a few seconds, the Tofino SA will start its factory reset sequence. The " 1/s", " 2/L", "V.24/R", "Mode" and "Fault" indicators will flash simultaneously while the factory reset is being performed.

□

Once the factory reset is complete, the " 1/s", " 2/L", "V.24/R", "Mode" and "Fault" indicators will turn off. This LED pattern confirms that the Tofino SA is passive and passing traffic without filtering. If the Mode LED is ON, repeat steps 1 through 3 above. If the LEDs are different from the above, please
contact technical support.

□

Decommission and sanitizeFollow decommission and sanitization tasks as described by your organization or contact your Network Administrator.

□

Perform records tracking sanitization tasks to remove records in related systems. For example: monitoring SNMP servers.

□

Disposal and reuseAfter usage, this product must be disposed of properly as electronic waste, in accordance with the current disposal regulations of your county, state and country.

□


For more information on the ConneXium Industrial Firewall, see https://www.se.com/us/en/download/document/NHA1572901/.

Schneider Electric ConneXium Industrial Firewall? | 施耐德電機Taiwan

  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings