How to Configure Microsoft Edge to Accept Insecure/Self-Assigned SSL Certificates
Issue
Microsoft Edge will not allow you manually access the PME web application due to the self-assigned certificate, giving the error message "It looks like the webpage might be having issues, or it may be moved permanently to a new address.
"ERR_SSL_KEY_USAGE_INCOMPATIBLE"
.
Error

Product Line
Power Monitoring Expert 2020
Power Monitoring Expert 2021
Power Monitoring Expert 2022
Power Monitoring Expert 2023

Environment
Power Monitoring Expert Web Applications
Microsoft Edge

Cause
By default, Microsoft Edge does not allow you to access the PME webpage while SSL is enabled, and HTTPS is required causing the webpage to no longer be accessible


Resolution
Note: This also allows you to reload legacy web pages

The following steps detail how to enable compatibility mode in Microsoft Edge
  1. Open Microsoft Edge
  2. Select the ellipses in the top right corner of the web browser and open the Settings option Settings
  3. Use the navigation windows on the left side to navigate to the "Appearance" page
  4. Scroll down on the main page to the "(IE Mode)" setting, and select the link "allow sites to be reloaded in Internet Explorer mode"Appearance
  5. A new tab will be opened with the "Internet Explorer compatibility" settings. Select the following option:
    1. Always - Let Internet Explorer open sites in Microsoft Edge
    2. Select the "Add" button, then type the URL https://Localhost/web and select "Add"
    3. Allow - Allow sites to be reloaded in Internet Explorer Mode (IE mode)
    4. Restart - For this setting change to take effect, restart your browserIE Compatibility
  6. Close and open the Microsoft Edge browser application to finalize the changes
  7. Once restarted, select the ellipses in the top right corner of the web browser and open the Settings option
  8. Use the navigation windows on the left side of the web browser's windows to navigate to the "Appearance" page
  9. Scroll down on the main page to the "(IE Mode)" setting, and turn the slider to onIE mode
  10. Navigate to the PME Web Applications page
  11. Select the internet explorer mode button at the top right of the browser windowPME Web Apps
  12. The browser page will be reloaded, and a small window will open in the top left with a couple of options
    1. Select the "Open this page in Compatibility view" and "Open this page in Internet Explorer mode next time" to ensure the window will be opened in IE Mode in the futureIE Mode Settings
Note: If your issue remains unresolved, please see FAQ000262649

施耐德電機Taiwan

探索更多
產品:
探索更多
產品:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings