我們的品牌

Impact-Company-Logo-English Black-01-177x54

歡迎造訪施耐德電機全球網站

歡迎訪問我們的網站
		
我们今天能为您提供什么帮助?
Site Code Generation Failure in EROE Studio

Problem:

  • I attempted to create a site code for the EROE license but failed. I received an error message: 'Cannot generate the Site Code!

SiteCode1

Solution:

  • Please temporarily turn off VPN services or other network services/adaptors. From the Control Panel, disable all network cards currently available in the computer, except for the main Ethernet network card. Then, try to get the Hardware Identifier from the Register application again.

SiteCode2

  • Check if any other network cards or modems are available and enabled in the Windows Device Manager. If so, proceed to disable those network cards as well.

SiteCode3

  • Temporarily, disable the VPN service using Task manager.
Detailed Steps:
  1. Open Task Manager: Press Ctrl + Shift + Esc to open the Task Manager.
  2. Locate VPN Process: In Task Manager, find the "Processes" tab. Look for any processes related to your VPN. They will often be named after your VPN provider (e.g., NordVPN, ExpressVPN, Tailscale VPN).
  3. End the Process: Right-click on the VPN process and select "End task
  • After obtaining the Softkey or Hardkey Site Code and activating the EROE Studio license, you can now enable all the network cards or network interfaces that you disabled. This won't affect the EROE Studio license at this point.

施耐德電機Taiwan

探索更多
系列:
探索更多
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings