我們的品牌

Impact-Company-Logo-English Black-01-177x54

歡迎造訪施耐德電機全球網站

歡迎訪問我們的網站
		
我们今天能为您提供什么帮助?
SoMove Launch Issue: "SoMove.Launcher" encountered an unexpected problem.

Article available in these languages: 西班牙文

Issue:

SoMove v2.10 or v2.11 will not launch after installation.

The error seen is:

Unhandled exception detected.

"SoMove.Launcher" encountered an unexpected problem.

ExceptionReport

Exception dialog created at: 10/29/2025 11:50.36AM

System.lO.FileNotFoundException: Could not bad file or assembly 'System.ServiceModel, Version=3.0.0.0, Culture=neutral,

PublicKeyToken=b77aScS61934e089' or one of its dependencies. The system cannot find the file specified.

File name: 'System.ServiceModel, Version=3.0.0.0, Culture=neutral, PublicKeyToken=b77aScS61934e08Y

at PowerSuite.Launcher.ShelLauncher.Main(String[] args)

This is the error message photo 1

Product Lines:

Altivar Drives

Lexium Servo

TeSys T Motor Starters

Environment:

Windows 11

Cause:

.NET Framework 3.5 is not installed on Windows 11

Resolution:

Enable .NET Framework 3.5 on Windows

1) Press the Start button on the taskbar.

2) Search for Windows Features and open it. The Turn Windows features on or off dialog box appears.

3) Select the .NET Framework 3.5 (includes .NET 2.0 and 3.0) check box, select OK, and reboot your computer if prompted.

4) Select the child items for Windows Communication Foundation (WCF) HTTP Activation and Windows Communication Foundation (WCF) Non-HTTP Activation.

Turn Windows features on or off photo 2

5) Restart the PC and Launch Somove.

If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.

If you are not located in North America, please contact your local Customer Care Center for assistance:

Support | Schneider Electric Global (se.com)

施耐德電機Taiwan

探索更多
系列:
探索更多
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings