PowerChute is flagged a vulnerable to CVE-2026-49844

Issue:

PowerChute is flagged a vulnerable to CVE-2026-49844

Product:

PowerChute Serial Shutdown 1.6

PowerChute Network Shutdown 5.2

Environment:

All supported operating systems.

Cause:

PowerChute Serial Shutdown v1.6 ships with Log4j version 2.25.4

PowerChute Network Shutdown v5.2 ships with Log4j version 2.25.3

Solution:

For PowerChute Serial Shutdown 1.6 on Windows:

  1. Download the attached file PCSS1.6_log4j_update.zip file
  2. Uncompress the file PCSS1.6_log4j_update.zip
  3. Open a command prompt as an administrator
  4. Change directory to the PCSS1.6_log4j_update directory that was created when the zip file PCSS1.6_log4j_update.zip was uncompressed.
  5. Run the command run_patch.cmd

The patch will remove the current log4j files and replace them with log4j version 2.26.1.

For PowerChute Network Shutdown 5.2 on Windows:

  1. Download the attached file PCNS5.2_log4j_update.zip file
  2. Uncompress the file PCNS5.2_log4j_update.zip
  3. Open a command prompt as an administrator
  4. Change directory to the PCSS5.2_log4j_update directory that was created when the zip file PCSS5.2_log4j_update.zip was uncompressed.
  5. Run the command run_patch.cmd

The patch will remove the current log4j files and replace them with log4j version 2.26.1.

NOTE: Files to update the PCSS 1.6 and PCNS 5.2 log4j files on Linux OS will be added soon.

施耐德電機Taiwan

附件
PCSS1.6_log4j_update.zip [2.02 MB]
PCNS5.2_log4j_update.zip [2.03 MB]
探索更多
系列:
探索更多
系列:
  • 產品文檔
  • 軟體下載
  • 產品選型工具
  • 產品替代和替換
  • 幫助和聯絡中心
  • 尋找我們的辦公室
  • 取得報價
  • 施耐德電機社群
  • 人才招募
  • 公司簡介
  • 舉報不當行為
  • 無障礙
  • 新聞中心
  • 投資者
  • 專業洞察
  • 台灣施耐德電機學院
  • 綠色影響力落差調查
  • Schneider Go Green 2025
  • 隱私政策
  • Cookie通告
  • 使用條款
  • Change your cookie settings