How can we help you today?
What are the difference between TIME and LTIME data types in Machine Expert?
Issue:
What are the difference between TIME and LTIME data types in Machine Expert?
Product Line:
Machine Expert
Resolution:
TIME is a 32 bit data type. The resolution is in milliseconds.
LTIME is a 64 bit data type. The resolution in nanoseconds.
Example of variable declarations:
var_0 AT %MD0: TIME; // %MD0 overlaps with %MW0 and %MW1
var_1 AT %MD1: TIME; // %MD1 overlaps with %MW2 and %MW3
var_2 AT %ML0: LTIME; // %ML0 overlaps with %MW0, %MW1, %MW2 and %MW3
var_3 AT %ML1: LTIME; // %ML1 overlaps with %MW4, %MW5, %MW6 and %MW7
If this FAQ did not solve your issue, you can chat with us at chat with us or e-mail us at customer.services@se.com to create a case with our Technical Support Team.
If you are not located in North America, please contact your local Customer Care Center for assistance:
Released for: Schneider Electric UK
Explore more
Range:
Explore more
Range:
Need help?
Product Selector
Quickly and easily find the right products and accessories for your applications.
Get a Quote
Start your sales inquiry online and an expert will connect with you.
Where to buy?
Easily find the nearest Schneider Electric distributor in your location.
Help Centre
Find support resources for all your needs, in one place.