Issue:
Line Side Terminal configurations for EZM Mains
Product Line:
EZ Meter-Pak Metering Equipment - EZM
Resolution:
EZM Mains are available in one of two configuration styles, either being supplied with Factory Install Lugs, or configured with Lug Landings Pads and Mounting Hardware provided (Lugs are to be ordered separately).
EZM Mains Supplied with Factory Installed Line Side Lugs include:
Main Circuit Breakers Main Fusible Switch Main Lugs Tap Boxes
------ ------ ------ ------ EZM1225TB EZM3225TB
EZM1400CB EZM3400CB EZM1400FS EZM3400FS EZM1400TB EZM3400TB
EZM1600CB EZM3600CB EZM1600FS EZM3600FS EZM1600TB EZM3600TB
EZM1800CB EZM3800CB EZM1800FS EZM3800FS EZM1800TB EZM3800TB
EZM11000CB EZM31000CB ------ ------ ------ ------
EZM11200GCBT# EZM31200GCBT# ------ ------ ------ ------
EZM11200JCBT# EZM31200JCBT# EZM11200FST# EZM31200FST# ------ ------
EZM11200GCBU* EZM31200GCBU* EZM11200FSB* EZM31200FSB* ------ ------
EZM11200JCBU* EZM31200JCBU* ------ ------ ------ ------
------ ------ ------ ------ EZM11600TB EZM31600TB
EZM11600GCBC EZM31600GCBC ------ ------ ------ ------
EZM11600JCBC EZM31600JCBC ------ ------ ------ ------
EZM12000CB EZM32000CB ------ ------ ------ ------
# TOP Entry Only Main Device
* Field Installable Lug Landing Kit (Cat. #: EZM1200ULL) is available. Requires that Lugs be ordered separately.
EZM Mains Supplied with NEMA Standard Lug Landing Pads with Mounting Hardware provided (Lugs are to be ordered separately) include:
Main Circuit Breakers Main Fusible Switch Main Lugs Tap Boxes
EZM1400CBU EZM3400CBU EZM1400FSU EZM3400FSU EZM1400TBU EZM3400TBU
EZM1600CBU EZM3600CBU EZM1600FSU EZM3600FSU EZM1600TBU EZM3600TBU
EZM1800CBU EZM3800CBU EZM1800FSU EZM3800FSU EZM1800TBU EZM3800TBU
EZM11000CBU EZM31000CBU ------ ------ ------ ------
------ ------ ------ ------ EZM11200TBU EZM31200TBU
EZM11200GCBE EZM31200GCBE ------ ------ ------ ------
EZM11200JCBE EZM31200JCBE EZM11200FSE EZM31200FSE ------ ------
EZM11600GCBU EZM31600GCBU ------ ------ ------ ------
EZM11600JCBU EZM31600JCBU ------ ------ ------ ------
EZM12000CBU EZM32000CBU ------ ------ EZM12000TB EZM32000TB
Line Side Terminal configurations for EZM Mains
Product Line:
EZ Meter-Pak Metering Equipment - EZM
Resolution:
EZM Mains are available in one of two configuration styles, either being supplied with Factory Install Lugs, or configured with Lug Landings Pads and Mounting Hardware provided (Lugs are to be ordered separately).
EZM Mains Supplied with Factory Installed Line Side Lugs include:
Main Circuit Breakers Main Fusible Switch Main Lugs Tap Boxes
------ ------ ------ ------ EZM1225TB EZM3225TB
EZM1400CB EZM3400CB EZM1400FS EZM3400FS EZM1400TB EZM3400TB
EZM1600CB EZM3600CB EZM1600FS EZM3600FS EZM1600TB EZM3600TB
EZM1800CB EZM3800CB EZM1800FS EZM3800FS EZM1800TB EZM3800TB
EZM11000CB EZM31000CB ------ ------ ------ ------
EZM11200GCBT# EZM31200GCBT# ------ ------ ------ ------
EZM11200JCBT# EZM31200JCBT# EZM11200FST# EZM31200FST# ------ ------
EZM11200GCBU* EZM31200GCBU* EZM11200FSB* EZM31200FSB* ------ ------
EZM11200JCBU* EZM31200JCBU* ------ ------ ------ ------
------ ------ ------ ------ EZM11600TB EZM31600TB
EZM11600GCBC EZM31600GCBC ------ ------ ------ ------
EZM11600JCBC EZM31600JCBC ------ ------ ------ ------
EZM12000CB EZM32000CB ------ ------ ------ ------
# TOP Entry Only Main Device
* Field Installable Lug Landing Kit (Cat. #: EZM1200ULL) is available. Requires that Lugs be ordered separately.
EZM Mains Supplied with NEMA Standard Lug Landing Pads with Mounting Hardware provided (Lugs are to be ordered separately) include:
Main Circuit Breakers Main Fusible Switch Main Lugs Tap Boxes
EZM1400CBU EZM3400CBU EZM1400FSU EZM3400FSU EZM1400TBU EZM3400TBU
EZM1600CBU EZM3600CBU EZM1600FSU EZM3600FSU EZM1600TBU EZM3600TBU
EZM1800CBU EZM3800CBU EZM1800FSU EZM3800FSU EZM1800TBU EZM3800TBU
EZM11000CBU EZM31000CBU ------ ------ ------ ------
------ ------ ------ ------ EZM11200TBU EZM31200TBU
EZM11200GCBE EZM31200GCBE ------ ------ ------ ------
EZM11200JCBE EZM31200JCBE EZM11200FSE EZM31200FSE ------ ------
EZM11600GCBU EZM31600GCBU ------ ------ ------ ------
EZM11600JCBU EZM31600JCBU ------ ------ ------ ------
EZM12000CBU EZM32000CBU ------ ------ EZM12000TB EZM32000TB
Released for: Schneider Electric USA