Issue:
Repair parts list for H464DS, series F6
Product Line:
Safety Switches
Resolution:
The repair parts for the H464DS, series F6 (F06) are as follows. No other parts are available:
Complete Line Base - 4056703650 (1 required; includes phenolic base, arc suppressors, lugs, rotor, switching blades, and fuse clips)
Line Base mounting screws - 4020514202 (8 required per line base)
Load Base Assembly - 4056677450 (1 required per phase; includes phynolic base, lugs, and fuse clips)
Load Base mounting screws - 4020514202 (2 required per load base)
Arc Suppressor Assembly - 4056677550 (1 required per phase)
Arc Suppressor mounting screw - 4020514501
Lug Assembly - 4025116251 (per lug)
Lug Assembly mounting screw - 2140122240 (per lug)
Switch Mechanism - 4056740150 (note: handle coupling, cover interlock defeat coupling, and lockplate gaskets may also need replacing)
Handle Coupling - 4056699850
Cover Interlock Defeat Coupling - 4056718850
Switch Mechanism mounting screws- 2194918121 (2 required)
Handle Assembly - 4056736850 (also recommend replacing lockplate gaskets)
Lockplate - 4056738901 (also recommend replacing lockplate gaskets)
Lockplate Gasket - 4050322802 (2 required) - Obsolete. Replaced with 4050322803
Lockplate mounting screws - 2194918121 (2 required)
Ground Lug - 4025101851 (2 required)
Ground Lug Mounting Screw - 4020514801
Repair parts list for H464DS, series F6
Product Line:
Safety Switches
Resolution:
The repair parts for the H464DS, series F6 (F06) are as follows. No other parts are available:
Complete Line Base - 4056703650 (1 required; includes phenolic base, arc suppressors, lugs, rotor, switching blades, and fuse clips)
Line Base mounting screws - 4020514202 (8 required per line base)
Load Base Assembly - 4056677450 (1 required per phase; includes phynolic base, lugs, and fuse clips)
Load Base mounting screws - 4020514202 (2 required per load base)
Arc Suppressor Assembly - 4056677550 (1 required per phase)
Arc Suppressor mounting screw - 4020514501
Lug Assembly - 4025116251 (per lug)
Lug Assembly mounting screw - 2140122240 (per lug)
Switch Mechanism - 4056740150 (note: handle coupling, cover interlock defeat coupling, and lockplate gaskets may also need replacing)
Handle Coupling - 4056699850
Cover Interlock Defeat Coupling - 4056718850
Switch Mechanism mounting screws- 2194918121 (2 required)
Handle Assembly - 4056736850 (also recommend replacing lockplate gaskets)
Lockplate - 4056738901 (also recommend replacing lockplate gaskets)
Lockplate Gasket - 4050322802 (2 required) - Obsolete. Replaced with 4050322803
Lockplate mounting screws - 2194918121 (2 required)
Ground Lug - 4025101851 (2 required)
Ground Lug Mounting Screw - 4020514801