Issue:
Design repair parts
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field repairable:
Meter Cover Assembly - 4053442852
Meter Cover Mounting Screw - 4020513001K (contains 10 screws; only one screw is required to secure the cover)
Branch Wiring Gutter Cover (Below Meter Cover) - 4056178101
Branch Wiring Gutter Cover Mounting Screw - 4020513001K (contains 10 screws; only one screw is required to secure the cover)
Utility Pullbox Cover - 4056181150 (includes cover latch)
Utility Pullbox Cover Sealing Screw - X1299
Load Center Cover Assembly - 4056181250
Load Center Cover Mounting Screws - (2) 2142217101
Dead Front Interior Trim - 4056177801
Dead Front Interior Trim Mounting Screw - 4020513001K (contains 10 screws; only two screws are required to secure the interior trim)
Load Center Interior - 4056162050 (main breaker not included)
Load Center Interior Mounting Screw - (4) 4020515602 and (1) 4020510201
Main Breaker - QOM2125VH
Meter Base - 4054102503 (phenolic base only - does not include line and load phase jaws)
Meter Base Mounting Screw - 2142717200
Meter Jaw - (4) 7329794850
Meter Jaw Mounting Keps Nut - (4) 2342702001
Meter Jaw Blade Guide - (4) 4052761901
Meter Sealing Ring - 2920910001
Left Line Side Phase Lug - 4025116051
Left Line Side Phase Lugs Mounting Bolt - 2271020242
Left Line Side Phase Lugs Mounting Keps Nut - 2342702001
Right Line Side Phase Lug and Line Side Neutral Lug are not field repairable.
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE
Design repair parts
Product Line:
Combination Service Entrance Devices
Resolution:
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED BELOW.
The parts listed here are the only parts considered field repairable:
Meter Cover Assembly - 4053442852
Meter Cover Mounting Screw - 4020513001K (contains 10 screws; only one screw is required to secure the cover)
Branch Wiring Gutter Cover (Below Meter Cover) - 4056178101
Branch Wiring Gutter Cover Mounting Screw - 4020513001K (contains 10 screws; only one screw is required to secure the cover)
Utility Pullbox Cover - 4056181150 (includes cover latch)
Utility Pullbox Cover Sealing Screw - X1299
Load Center Cover Assembly - 4056181250
Load Center Cover Mounting Screws - (2) 2142217101
Dead Front Interior Trim - 4056177801
Dead Front Interior Trim Mounting Screw - 4020513001K (contains 10 screws; only two screws are required to secure the interior trim)
Load Center Interior - 4056162050 (main breaker not included)
Load Center Interior Mounting Screw - (4) 4020515602 and (1) 4020510201
Main Breaker - QOM2125VH
Meter Base - 4054102503 (phenolic base only - does not include line and load phase jaws)
Meter Base Mounting Screw - 2142717200
Meter Jaw - (4) 7329794850
Meter Jaw Mounting Keps Nut - (4) 2342702001
Meter Jaw Blade Guide - (4) 4052761901
Meter Sealing Ring - 2920910001
Left Line Side Phase Lug - 4025116051
Left Line Side Phase Lugs Mounting Bolt - 2271020242
Left Line Side Phase Lugs Mounting Keps Nut - 2342702001
Right Line Side Phase Lug and Line Side Neutral Lug are not field repairable.
NOTE: WIRING DIAGRAM AND LABELS ARE NOT INCLUDED ON THE PARTS LISTED ABOVE
Released for: Schneider Electric USA

