Our Brands

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
What are the 3 stop categories according to NFPA 79?
Issue:
What are the different NFPA 79 stop categories?

Product Line:
Operating Mechanisms and Disconnect Switches

Environment:
Disconnect Switches

Resolution:
Category 0 is an uncontrolled stop by immediately removing power to the machine actuators.
Category 1 is a controlled stop with power to the machine actuators available to achieve the stop then remove the power when the stop is achieved.
Category 2 is a controlled stop with power left available to the machine actuators.

Schneider Electric USA

Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings