How do the contacts operate on the 9001BW82Y?
Issue:
Contact Operation in a 9001BW pendant station

Product Line:
Square D 9001 BW Pendant Stations

Environment:
Type BW Pendant Stations

Resolution:
Each of the two buttons has two staggered NO contacts.  Depress a button and the first contact closes (speed 1), continue depressing and the 2nd contact closes (speed 2). The buttons are mechanically interlocked so that both cannot be pushed at the same time.