Our Brands

Schneider Electric USA Website

Welcome to our website.
		
How can we help you today?
What is the difference between QOU miniature breaker terminal adapters QOURT and QOURTB?
Product line:
Circuit breakers

Resolution:
The `B` indicates bulk package quantity of 80 QOURT per order quantity of one (1).

Schneider Electric USA

Explore more
Range:
Users group

Discuss this topic with experts

Visit our community and get advice from experts and peers on this topic and more
Explore more
Range:
  • Products Documentation
  • Software Downloads
  • Product Selector
  • Product Substitution and Replacement
  • Help and Contact Center
  • Where to buy
  • Get a Quote
  • Find our Offices
  • Schneider Electric Community
  • Careers
  • Company Profile
  • Report a misconduct
  • Accessibility
  • Newsroom
  • Investors
  • EcoStruxure
  • Job Search
  • Blog
  • Tech Support: 877-342-5173
  • Privacy Policy
  • Cookie Notice
  • Terms of use
  • Change your cookie settings